Agilent Technologies 16800 Series Manuale Utente

Navigare online o scaricare Manuale Utente per Multimetri Agilent Technologies 16800 Series. Agilent Technologies B4656A FPGA Dynamic Probe for Altera Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 8
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Agilent Technologies
B4656A FPGA Dynamic Probe for Altera
Data Sheet
The challenge
You rely on the insight a logic
analyzer provides to understand
the behavior of your FPGA in
the context of the surrounding
system. Design engineers
typically take advantage of the
programmability of the FPGA to
route internal nodes to a small
number of physical pins that a
logic analyzer can measure. While
this approach is very useful, it
has significant limitations.
Since pins on the FPGA are
typically an expensive
resource, there are a relatively
small number available for
debug. This limits internal
visibility (i.e. one pin is
required for each internal
signal to be probed).
When you need to access
different internal signals, you
must change your design to
route these signals to the
available pins. This can be time
consuming and can affect the
timing of your FPGA design.
Finally, the process required
to map the signal names from
your FPGA design to the logic
analyzer setup is manual and
tedious. When new signals
are routed out, you need to
Figure 1. FPGA dynamic probe for Altera used in conjunction with an Agilent logic
analyzer provides the most effective solution for simple through complex debugging of
systems incorporating Altera FPGAs.
manually update these signal
names on the logic analyzer,
which takes additional time
and is a potential source of
confusing errors.
Vedere la pagina 0
1 2 3 4 5 6 7 8

Sommario

Pagina 1 - Agilent Technologies

Agilent TechnologiesB4656A FPGA Dynamic Probe for AlteraData SheetThe challengeYou rely on the insight a logicanalyzer provides to understandthe behav

Pagina 2

2FPGA dynamic probe lets you:View internal activity – With a logic analyzer, you are normallylimited to measuring signals atthe periphery of the FPGA.

Pagina 3

3Design step 1: Configure the logicanalyzer interface file and coreparametersYou need to create a logicanalyzer interface file with the logic analyzer

Pagina 4 - (continued)

4A quick tour of the application (continued)Design step 3: Assign logic analyzerinterface bank parametersAssign internal signals to eachbank in the lo

Pagina 5

5A quick tour of the application (continued)Measurement setup step 1: Establisha connection between the logicanalyzer and the logic analyzerinterface

Pagina 6

6A quick tour of the application (continued)Setup complete: Make measurementsQuickly change which signal bankis routed to the logic analyzer. Asingle

Pagina 7 - Ordering information

7Agilent B4656A specifications and characteristicsSupported logic analyzersStandalone logic analyzers 1680 Series, 1690 Series, 16800 SeriesModular l

Pagina 8 - Remove all doubt

www.agilent.comFor more information on AgilentTechnologies’ products, applications or services, please contact your localAgilent office. The complete

Commenti su questo manuale

Nessun commento