Agilent Technologies E8364C Manuale Utente

Navigare online o scaricare Manuale Utente per Misurazione, test & controllo Agilent Technologies E8364C. the Agilent E8363C datasheet. [en] Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 65
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Test Equipment Solutions Datasheet
Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of
quality test & measurement (T&M) equipment. We stock all major equipment types such as
spectrum analyzers, signal generators, oscilloscopes, power meters, logic analysers etc from
all the major suppliers such as Agilent, Tektronix, Anritsu and Rohde & Schwarz.
We are focused at the professional end of the marketplace, primarily working with customers
for whom high performance, quality and service are key, whilst realising the cost savings that
second user equipment offers. As such, we fully test & refurbish equipment in our in-house,
traceable Lab. Items are supplied with manuals, accessories and typically a full no-quibble 2
year warranty. Our staff have extensive backgrounds in T&M, totalling over 150 years of
combined experience, which enables us to deliver industry-leading service and support. We
endeavour to be customer focused in every way right down to the detail, such as offering free
delivery on sales, covering the cost of warranty returns BOTH ways (plus supplying a loan
unit, if available) and supplying a free business tool with every order.
As well as the headline benefit of cost saving, second user offers shorter lead times, higher
reliability and multivendor solutions. Rental, of course, is ideal for shorter term needs and
offers fast delivery,
flexibility, try-before-you-buy, zero capital expenditure, lower risk and off
balance sheet accounting. Both second user and rental improve the key business measure of
Return On Capital Employed.
We are based near Heathrow Airport in the UK from where we supply test equipment
worldwide. Our facility incorporates Sales, Support, Admin, Logistics and our own in-house
Lab.
All products supplied by Test Equipment Solutions include:
- No-quibble parts & labour warranty (we provide transport for UK mainland addresses).
- Free loan equipment during warranty repair, if available.
- Full electrical, mechanical and safety refurbishment in our in-house Lab.
- Certificate of Conformance (calibration available on request).
- Manuals and accessories required for normal operation.
- Free insured delivery to your UK mainland address (sales).
- Support from our team of seasoned Test & Measurement engineers.
- ISO9001 quality assurance.
Test equipment Solutions Ltd
Unit 8 Elder Way
Waterside Drive
Langley
Berkshire
SL3 6EP
T: +44 (0)1753 596000
F: +44 (0)1753 596001
Email: info@TestEquipmentHQ.com
Web: www.TestEquipmentHQ.com
Vedere la pagina 0
1 2 3 4 5 6 ... 64 65

Sommario

Pagina 1

Test Equipment Solutions DatasheetTest Equipment Solutions Ltd specialise in the second user sale, rental and distribution of quality test & measu

Pagina 2 - Network Analyzers

9E8362/3/4CCorrected system performance with 3.5 mm connectorsDescription Specification (dB) 45 MHz to 2 GHz 2 to 20 GHz 20 to 26.5 GHzDirectivit

Pagina 3 - Some Definitions

10E8362/3/4CCorrected system performance with 3.5 mm connectors continuedDescription Specification (dB) 45 MHz to 2 GHz 2 to 20 GHz 20 to 26.5 GHzD

Pagina 4 - Table of Contents

11E8362/3/4CUncorrected system performance 1 Description Specification Supplemental informationDirectivity Typical: 10 to 45 MHz2 23 dB 23 dB 4

Pagina 5

12E8362/3/4CUncorrected system performance 1 continued Description Specification Supplemental informationCrosstalk1 - standard 10 to 45 MHz2 65 dB 4

Pagina 6

13E8362/3/4C Test port output Description Specification Supplemental information Standard 014 UNL UNL and 014Frequency range E8362C

Pagina 7

141. Source output performance on port 1 only. Port 2 output performance is typical, except for power level accuracy which is characteristic.E8362

Pagina 8

15E8362/3/4C Test port input Description Specification Supplemental information Standard 014 UNL UNL and 014Test port noise floor 1 10

Pagina 9

16E8362/3/4C Test port input continued Description Specification Supplemental information Standard, 014, UNL UNL and 014Direct receiver

Pagina 10 - E8362/3/4C

17E8362/3/4C Test port input continued Description Specification Supplemental information Standard 014 UNL UNL and 014Trace noise magni

Pagina 11

18E8362/3/4C Test port input continuedGroup delay 1Description Specification Supplemental information (typical)Aperture (selectable) (freq

Pagina 12

Agilent PNA Microwave Network AnalyzersData SheetThis document describes the performance and features of the Agilent Technologies PNA microwave netw

Pagina 13

19E8362/3/4CTest port input continued Dynamic accuracy (specifications) 1Applies to input ports 1 and 2, accuracy of the test port input power readin

Pagina 14

20E8361C Corrected system performanceThe specifications in this section apply for measure-ments made with the Agilent E8361C PNA Series microwave netw

Pagina 15

21E8361C Corrected system performance with 1.85 mm connectorsDescription Specification (dB) 10 to 200 MHz1 200 MHz to 2 GHz 2 to 20 GHz 20 to 30 G

Pagina 16

22E8361C Corrected system performance with 1.85 mm connectors continuedDescription Specification (dB) 30 to 40 GHz 40 to 50 GHz 50 to 60 GHz 60 t

Pagina 17

23E8361C Corrected system performance with 1.85 mm connectors continuedDescription Specification (dB) 10 to 200 MHz1 200 MHz to 2 GHz 2 to 20 GHz

Pagina 18

24E8361C Corrected system performance with 1.85 mm connectors continuedDescription Specification (dB) 30 to 40 GHz 40 to 50 GHz 50 to 60 GHz 60 to

Pagina 19

25E8361C Corrected system performance with 1.85 mm connectors continuedDescription Specification (dB) 10 to 45 MHz1 45 MHz to 2 GHz 2 to 10 GHz 10

Pagina 20

26E8361C Corrected system performance with 1.85 mm connectors continuedDescription Specification (dB) 20 to 35 GHz 35 to 50 GHz 50 to 60 GHz 60 to

Pagina 21 - Corrected system performance

27E8361C Corrected system performance with 1.85 mm connectors continuedDescription Specification (dB) 10 to 45 MHz1 45 MHz to 2 GHz 2 to 10 GHz 10

Pagina 22 - Magnitude

28E8361C Corrected system performance with 1.85 mm connectors continuedDescription Specification (dB) 20 to 35 GHz 35 to 50 GHz 50 to 60 GHz 60 to

Pagina 23

2Some DefinitionsAll specifications and characteristics apply over a 25 °C ±5 °C range (unless otherwise stated) and 90 minutes after the instrument

Pagina 24

29E8361C Corrected system performance with 2.4 mm connectorsDescription Specification (dB) 10 to 200 MHz1 200 MHz to 2 GHz 2 to 20 GHz 20 to 40 GH

Pagina 25

30E8361C Corrected system performance with 2.4 mm connectors continuedDescription Specification (dB) 10 to 200 MHz1 200 MHz to 2 GHz 2 to 20 GHz 2

Pagina 26

31E8361C Corrected system performance with 2.4 mm connectors continuedDescription Specification (dB) 45 MHz to 2 GHz 2 to 20 GHz 20 to 40 GHz 40 t

Pagina 27

32E8361C Corrected system performance with 2.4 mm connectors continuedDescription Specification (dB) 45 MHz to 2 GHz 2 to 20 GHz 20 to 40 GHz 40 t

Pagina 28

33E8361C Uncorrected system performance 1 Description Specification Typical Directivity 10 to 45 MHz 2 22 dB 22 dB 45 MHz to 2 GHz 24 d

Pagina 29

34E8361C Uncorrected system performance 1 continued Description Specification Typical Load match - Option 014 10 to 45 MHz 2 5.5 dB 5.5 dB

Pagina 30

35E8361C Uncorrected system performance 1 continued Description Specification Supplemental informationReflection tracking Typical: 10 to 45 M

Pagina 31

36E8361CTest port output Description Specification Option 014 Option UNL Supplemental Standard and Option 014 informationFrequency

Pagina 32

37E8361CTest port output continued Description Specification Supplemental informationPhase noise (10 kHz offset from center frequency, nominal

Pagina 33

38E8361C Test port input Description Specification Option 014 or Option 016 Supplemental Standard Option UNL and 014 informationTest

Pagina 34

3Table of ContentsE8362/3/4CCorrected system performance . . . . . . . . . . . . . . . . 4 System dynamic range . . . . . . . . . . . . . . . . . .

Pagina 35 - continued

39E8361C Test port input continued Description Specification Option 014 or Supplemental Standard Option 014 and UNL (typ.) information D

Pagina 36

40E8361C Test port input continued Description Specification Option UNL Supplemental Standard or Option 014 and Option 014 information Thir

Pagina 37 - Test port output

411. Stability is defined as a ratio measurement measured at the test port.E8361C Test port input continued Description Specification Suppleme

Pagina 38

42E8361C Test port input continuedGroup delay 1 Description Specification Supplemental information (typical)Aperture (selectable) (fre

Pagina 39 - Test port input

43E8361C Test port input continued Dynamic accuracy (specification)1Applies to input ports 1 and 2, accuracy of the test port input power reading

Pagina 40

44E8361C Test port input continued Dynamic accuracy (specification)1Applies to input ports 1 and 2, accuracy of the test port input power reading

Pagina 41

45E8361C Test port input continued Dynamic accuracy (specification)1Applies to input ports 1 and 2, accuracy of the test port input power reading

Pagina 42

46E8361C Test port input continued Dynamic accuracy (specification)1Applies to input ports 1 and 2, accuracy of the test port input power reading

Pagina 43

47Microwave PNA SeriesGeneral information Description Supplemental informationSystem IF bandwidth range 1 Hz to 40 kHz, nominalRF connectors E8362C

Pagina 44

48Microwave PNA SeriesGeneral information continued Description Supplemental informationNon-operating storage environment Temperature -40 to +70 °C

Pagina 45

4E8362/3/4C Corrected system performanceThe specifications in this section apply for measure-ments made with the Agilent E8362/3/4C PNA Series microwa

Pagina 46

491. Measured at –5 dBm test port power.2. Pulse input connectors are operational only with Option H08 (Pulsed Measurement Capability) enabled.3. B

Pagina 47

50Microwave PNA SeriesRear panel continuedDescription Supplemental information10 MHz reference in Input frequency 10 MHz ±10 ppm, typ. Input power

Pagina 48 - Microwave PNA Series

51Microwave PNA SeriesMeasurement throughput summaryCycle time vs. IF bandwidth 1 Cycle time vs. number of points 1Instrument state: preset condition

Pagina 49

52Frequency Converter Application (Option 083) cycle time for fixed-IF measurements (s)1 Number of points 101 201 401

Pagina 50

53Microwave PNA SeriesMeasurement capabilitiesNumber of measurement channelsThirty-two independent measurement channels. A measurement channel is coup

Pagina 51

54Microwave PNA SeriesAutomationMethodsControlling via internal analyzer executionWrite applications that can be executed from within the analyzer via

Pagina 52

55amount in degrees.Microwave PNA SeriesData accuracy enhancementMeasurement calibrationMeasurement calibration significantly reduces measurement unce

Pagina 53 - 2. Typical performance

56Microwave PNA SeriesSystem capabilitiesImproved graphical user interfaceAll PNA Series instruments (PNA-X, PNA-L, PNA) now employ the same graphical

Pagina 54

57Frequency-offset (Option 080)This option enables the PNA Series microwave network analyzers to set the source frequency independently from where the

Pagina 55

58IF Access (Option H11)Provides hardware to enable antenna, point-in-pulse, and pulse-profile measurements, as well as broadband millimeter-wave meas

Pagina 56

5E8362/3/4C Corrected system performance continued1. The system dynamic range is calculated as the difference between the noise floor and the source

Pagina 57

Microwave PNA SeriesSimplified test set block diagram Standard power range Extended power range and bias-tees (Option UNL) Configuration tes

Pagina 58

SourceSwitch/splitter/levelerReference receiverReference receiverMeasurement receiversCplrarmBias-teeSource attenuator1ABias-teeSource attenuator1BR1

Pagina 59

Ordering guide for PNA series Network analyzersOptionsTo add options to a product, order the corresponding item number. Description For E8362C F

Pagina 60

62Test port cable specifications Connector Type Frequency Length2 Return Insertion loss Stabillty1,2 ±Phase (Test port to device) (GHz)

Pagina 61 - Test port 2

63Test port cable specifications continued Connector Type Frequency Length2 Return Insertion loss Stabillty1,2 ±Phase (Test port to devic

Pagina 62 - Network analyzers

Microsoft®, Windows® and MS-DOS® are U.S. registered trademarks of Microsoft Corporation.Intel® and Pentium® are US registered trademarks of Intel Cor

Pagina 63

6E8362/3/4C Receiver dynamic range1Description Specification (dB) Typical (dB) at direct Supplemental information at test port2 receiver ac

Pagina 64

7E8362/3/4CCorrected system performance with 2.4 mm connectorsDescription Specification (dB) 45 MHz to 2 GHz 2 to 20 GHz 20 to 40 GHz 40 to 50 GHz

Pagina 65 - Revised: August 14, 2008

8E8362/3/4CCorrected system performance with 2.4 mm connectors continuedDescription Specification (dB) 45 MHz to 2 GHz 2 to 20 GHz 20 to 40 GHz 40

Commenti su questo manuale

Nessun commento