Infiniium 54800 SeriesOscilloscope Probes, Accessories, and OptionsSelection Guide Data SheetTable of ContentsProbe Compatibility Table ...
High-Frequency Active Differential/Single-Ended Probe SystemAgilent 1130A/31A/32A/34A InfiniiMax High-Performance Active Probe System• The Agilent Inf
High-Frequency Active Differential/Single-Ended Probe SystemAgilent 1130A/31A/32A/34A InfiniiMax High-Performance Active Probe SystemSpecificationsOpe
High-Frequency Active Differential/Single-Ended Probe SystemAgilent 1130A/31A/32A/34A InfiniiMax High-Performance Active Probe SystemOrdering Informat
13Two new high-bandwidth InfiniiMax IISeries probe amplifiers have been added tothe InfiniiMax product line. InfiniiMax Iprobe amplifiers and probe he
14High-Frequency Active Differential/Single-Ended Probe SystemAgilent 1168A/69A InfiniiMax II High-Performance Active Probe SystemSpecificationsOperat
15High-Frequency Active Differential/Single-Ended Probe SystemAgilent 1168A/69A InfiniiMax II High-Performance Active Probe SystemOrdering Information
16Figure 3.8. Agilent 1155A for fine-pitch ICs, SMDs, and densecircuit boards.High-Frequency Active Single-Ended Voltage ProbesAgilent 1155A Active Si
17SpecificationsOperating CharacteristicsBandwidth (–3 dB) dc to ≥ 750 MHzSystem bandwidth 500 MHz with 600 MHz 54830B/D, 31B/D scopes670 MHz with 1 G
18High-Frequency Active Single-Ended Voltage ProbesAgilent 1156A/57A/58A High-Bandwidth, Active Single-Ended Voltage• Ideal for a range of hi-speed ap
19SpecificationsOperating CharacteristicsBandwidth (–3 dB) 1156A: > 1.5 GHz; 1157A: > 2.5 GHz; 1158A: > 4 GHzSystem bandwidth (–3 dB) 1156A w
For ordering information when replac-ing your probe or probe accessory:Refer directly to the page numberlisted in the table of contents foryour probe
20Twelve 130 Ωresistive signalpins (orange)*Accessories SuppliedTwo solderable-tip5 cm resistive signal leads*Two socket-end 5 cmresistive signal lead
21High-Frequency Passive Voltage ProbeAgilent 54006A 6 GHz Resistor Divider ProbeThe Agilent 54006A allows you toprobe signals up to 6 GHz usingreplac
22Differential Voltage Probes OverviewDifferential probes are activeprobes with two inputs, one posi-tive and one negative, as well as aseparate groun
23Reliable Probing of Low-Bandwidth Signals The Agilent 1153A is a 1:1 FETdifferential probe with 200 MHzbandwidth and 3000:1 CMRR(Common Mode Rejecti
24SpecificationsOperating CharacteristicsBandwidth (–3 dB) dc to 200 MHz [1]Rise time 1.75 ns calculated from tr= (0.35/bandwidth)dc gain accuracy* 2%
25Ordering InformationProbe and AccessoriesPart # Description Quantity1153A 200 MHz differential probe 15959-9335 Long (5.5 inch) test lead 5IC clips:
26Current Probes OverviewCurrent probes sense the currentflowing through a conductor andconvert it to a voltage that can beviewed and measured on an o
27Within Budget, Without CompromiseThe low-cost 1146A probeexpands oscilloscope applicationsin industrial, automotive andpower environments and is ide
28SpecificationsOperating CharacteristicsCurrent range* 100 mV/A: 100 mA to 10 A peak; 10 mV/A: 1 to 100 A peakOutput signal 1000 mV peak maxac curren
29Accurate Current MeasurementsWithout Breaking the CircuitThe 1147A is a wide bandwidth,dc to 50 MHz, current probe. Theprobe offers flat frequencyre
General Purpose Probes OverviewPassive voltage probes are usedfor general purpose probing andare made with passive compo-nents only such as wires, con
30Operating CharacteristicsBandwidth (–3 dB) dc to 50 MHzRise time17 nsAccuracy* ±1% of reading ±1 mVMaximum continuous current 15 A (acrms + dc) Refe
31High-Voltage Passive Probes OverviewHigh-voltage probes are used forvoltages higher than can be han-dled safely with general-purpose10:1 passive pro
32The 10076A provides the features you need to capturefast, high-voltage signals. Itscompact design makes it easy toprobe today’s small, power electro
33SpecificationsOperating CharacteristicsBandwidth (–3 dB) 50 MHzRise time (calculated) < 7 nsAttenuation ratio 1000:1Input resistance 100 MΩ (when
34Mixed-Signal Oscilloscope Logic Probe Kit• Same cable used for high-performance Agilent logic analyzers• Flying leads offer flexibility and convenie
35Agilent E5396A Half-Size Soft Touch Connectorless Logic Probe• 17 channels, single-ended clockand data • < 0.7 pF equivalent load capacitance • C
36Probing AccessoriesWedge AdaptersAgilent Wedge Probe Adapters• Secure connection to 0.5 mm and0.65 mm TQFP and PQFP devices• Won’t fall off, short a
37Figure 9.3. Horizontal and vertical versionsof the PC board mini-probe socket make iteasy to fit into your target board.0.5 mm IC Clips• Extremely s
38EZ-Probe Positioner• Stable X, Y, Z positioning• 3-D joystick, 3:1 motion reduction• Compatible with all Agilent hand-held probesThe revolutionary E
39Logic Analyzer/Oscilloscope Time Correlation• Verify correct logical relationshipsbetween analog and digital portions of a design• Cross-trigger and
Built for ReliabilityThese general purpose replace-ment devices are built and testedfor high reliability. Kevlarstrengthener has been added tothe prob
40VoiceControl• Hands-free scope operation• Speaker and gender independent• Uses simple English commandsIf you’re making multi-channelmeasurements on
411184A TestmobileThe Agilent 1184A testmobilegives you a convenient means oforganizing and transporting yourInfiniium oscilloscope and acces-sories.
42Related LiteraturePublication Title Publication Type Publication NumberAgilent Technologies Digital and Selection Guide 5988-8460EN/ENUSMixed Signa
SpecificationsSystemModel Bandwidth Division Scope CompensationNumber Type of Probe (scope +probe) Ratio Input R Input C Input R Range Length1160A Hig
Ordering InformationProbes and AccessoriesPart # Description Quantity1160A 10:1, 10 MΩ, 1.5 m, miniature passive probe 11161A 10:1, 10 MΩ, 1.5 m, mini
Suited for Today’s ICsAn exceptionally small and lightprobe tip (<1 gram) and an ultrathin cable make the 117XA familyideal for connecting to and p
SpecificationsOperating CharacteristicsApproximate propagation delay 1171A: 6.5 nsMaximum input voltage 40 V (dc + peak ac), CAT ISafety Meets IEC10
High-Frequency Voltage Probes OverviewActive voltage probes contain anactive component, usually a field-effect transistor (FET), and there-fore need t
Commenti su questo manuale