OPERATING MANUAL
240 VOLT ELECTRONIC LOAD MODULE
Agilent Model 60503B
FOR MODULES WITH SERIAL NUMBERS:
3119A-00101 AND ABOVE
Agilent Part No. 60503-90007 Printed in U.S.A.
Microfiche No. 60503-90008 June, 1991
Vedere la pagina 0
1 2 3 4 5 6 ... 10 11

Sommario

Pagina 1 - OPERATING MANUAL

OPERATING MANUAL240 VOLT ELECTRONIC LOAD MODULEAgilent Model 60503BFOR MODULES WITH SERIAL NUMBERS:3119A-00101 AND ABOVE

Pagina 2 - DECLARATION OF CONFORMITY

8Table 60503-4. Calibration InformationRanges andCalibration PointsVariables VariablesValuePower SupplySettingsCurrentShuntHigh Current Range Hi_curr

Pagina 3 - 240-Volt Module

9Agilent Sales and Support OfficeFor more information about Agilent Technologies test and measurement products, applications, services, and for a cur

Pagina 4

DECLARATION OF CONFORMITYaccording to ISO/IEC Guide 22 and EN 45014 Manufacturer’s Name: Agilent Technologies Manufacturer’s Address: New Jersey Divi

Pagina 5

1240-Volt ModuleAbout This ManualThis manual provides information for the Agilent 60503B 250-Watt Electronic Load Module. It is designed as asuppleme

Pagina 6

2Table 60503-1. Specification and Supplemental CharacteristicsSPECIFICATIONSDC Input Rating:Current: 0 to 10 AVoltage: 3 V to 240 V (minimum dc o

Pagina 7

3Table 60503-1 Specifications and Supplemental Characteristics (continued)Transient Operation:Continuous Mode Frequency Range: 0.25 Hz to 10 kHz F

Pagina 8

4Table 60503-1 Specifications and Supplemental Characteristics (continued)External Analog Programming 0 to 10 V (dc or ac):Bandwidth: 10 kHz (3 db fre

Pagina 9

5Table 60503-1 Specifications and Supplemental Characteristics (continued)Current Slew Rate:*Rate # 10 A Range Step 1 A Range Step Transition Time1

Pagina 10

6Table 60503-1 Specifications and Supplemental Characteristics (continued)Source Turn-On Current Overshoot: Less than 5% of final value (in CC and CR

Pagina 11

7Table 60503-2. Programming Ranges (continued)Function Front Panel Front Panel HPSL Command Range of ValuesKey Display (Short Form)Transient Operatio