Chapter 7: Trigger on a 4 Bit Serial Pattern
Define the Trigger Conditions: Trigger on a 4-bit Serial Pattern
Define the Trigger Conditions: Trigger on a
4-bit Serial Pattern
A serial pattern is a consecutive sequence of events. If the events do
not occur in order, the state analyzer will never trigger.
1 Select the Trigger tab.
2 Under the Trigger Functions tab, scroll to and click on
‘Find n-bit serial pattern’.
1
2
3
4
If 0 is found, go to sequence level 2
0
1
1
0
Trigger
If 1 is found, go to sequence level 3
If 0 is found, go to sequence level 4
If 1 is found, trigger the analyzer
/0
/1
/0
/1
Else If 0 is not found, go to level 1
Else If 1 is not found, go to level 1
Else If 0 is not found, go to level 1
Else If 1 is not found, go to level 1