1-3
Troubleshooting
Getting Started with Troubleshooting
Getting Started with Troubleshooting
Referring to Table1-1:
determine where to begin troubleshooting
work on problems in the order they are presented in the table
use the descriptions provided in this chapter that explain how the signal generator operates, and
the function of each assembly: the overall description (page 1-85), the synthesis loop (page 1-95),
the RF path (page 1-103), and self–test (page 1-115).
Running Self-Test
1. On the instrument front panel, press the Utility hardkey.
2. Select the following softkeys:
a.
Instrument Info/Help Mode
b. Self Test
c. Run Complete Self Test
Table 1-1
If able to run self-test... Go to this section...
Run Self-Test “Running Self-Test” on page 1-3 and refer to
“Self–Test Failures and Related Troubleshooting” on page 1-7.
If unable to run self-test, check... Go to this section...
Power supply failures
A18 CPU turn-on failures
Front panel display or keyboard operations
“Power Supply Troubleshooting” on page 1-17
A18 CPU Turn–On Test” on page 1-4
“Front Panel Display Assembly Troubleshooting” on page 1-11
If other conditions occur... Go to this section...
Unlocked Conditions
Unleveled Conditions
Adjustment Problems
Performance Test Problems
“Troubleshooting Unlocks” on page 1-64
“Troubleshooting Unlevels” on page 1-67
“Troubleshooting Adjustment Problems” on page 1-71
“Troubleshooting Performance Test Problems” on page 1-74