Command Reference
Pulse Modulation Subsystem ([:SOURce])
Chapter 4288
Pulse Modulation Subsystem ([:SOURce])
:PULM:INTernal[1]:DELay
Supported PSG-A Series
[:SOURce]:PULM:INTernal[1]:DELay <num>[<time suffix>]|UP|DOWN
[:SOURce]:PULM:INTernal[1]:DELay?
This command sets the pulse delay of the internally generated pulse modulation source.
The optional variable [<time suffix>] accepts nS (nanoseconds) to S (seconds).
*RST
+
0.00000000E
+
000
Key Entry
Pulse Delay
Remarks The range value is dependent on the value set for the pulse period.
Refer to “:PULM:INTernal[1]:PERiod” on page 290 for pulse period
settings.
Refer to “:PULM:INTernal[1]:DELay:STEP” on page 289 for setting
the value associated with the UP and DOWN choices.
Range Internal Free Run:
(pulse period
20 nS) to (pulse period
20 nS)
Internal Triggered & Doublet: 70nS to (pulse period
20 nS)
Choices <num>[<time suffix>] UP DOWN