Agilent Technologies E3640A Manuale di Servizio

Navigare online o scaricare Manuale di Servizio per Alimentatori Agilent Technologies E3640A. Agilent Technologies E3640A Technical data Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - Supplies

Agilent TechnologiesAgilent E364xA Single Output DC Power SuppliesUser’s and Service Guide

Pagina 2

X E364xA User’s and Service GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Pagina 3 - Safety Symbols

3 Remote Interface Reference Simplified Programming Overview78 E364xA User’s and Service GuideReading a query responseOnly the query commands (comman

Pagina 4 - Safety Considerations

Remote Interface Reference 3 Simplified Programming OverviewE364xA User’s and Service Guide 79Power supply programming rangesThe SOURce subsystem requ

Pagina 5

3 Remote Interface Reference Simplified Programming Overview80 E364xA User’s and Service GuideTable 3 - 3 Agilent E3641A/E3643A/E3645A programming ra

Pagina 6 - Environmental Conditions

Remote Interface Reference 3 Using the APPLy CommandE364xA User’s and Service Guide 81Using the APPLy CommandThe APPLy command provides the most stra

Pagina 7 - Regulatory Markings

3 Remote Interface Reference Output Settings and Operation Commands82 E364xA User’s and Service GuideOutput Settings and Operation CommandsThis secti

Pagina 8

Remote Interface Reference 3 Output Settings and Operation CommandsE364xA User’s and Service Guide 83CURRent:STEP {<numeric value>|DEFault}Set t

Pagina 9

3 Remote Interface Reference Output Settings and Operation Commands84 E364xA User’s and Service GuideExampleThe following program segment shows how t

Pagina 10

Remote Interface Reference 3 Output Settings and Operation CommandsE364xA User’s and Service Guide 85To set the step size to the minimum resolution, s

Pagina 11 - Table of Contents

3 Remote Interface Reference Output Settings and Operation Commands86 E364xA User’s and Service GuideVOLTage:TRIGgered? [MINimum|MAXimum]Query the tr

Pagina 12 - 2 Operation and Features

Remote Interface Reference 3 Output Settings and Operation CommandsE364xA User’s and Service Guide 87Before sending this command, lower the output vol

Pagina 13 - 3 Remote Interface Reference

E364xA User’s and Service Guide XITable of Contents1 Getting StartedIntroduction 2Standard Shipped Items 6Options 6Accessories 7Pr

Pagina 14

3 Remote Interface Reference Triggering88 E364xA User’s and Service GuideTriggeringThe power supply’s triggering system allows a change in voltage an

Pagina 15 - 6 Tutorial

Remote Interface Reference 3 TriggeringE364xA User’s and Service Guide 89• To trigger the power supply from the remote interface (GPIB or RS- 232) aft

Pagina 16 - 8 Service and Maintenance

3 Remote Interface Reference Triggering90 E364xA User’s and Service GuideTriggering commandsINITiateCause the trigger system to initiate. This comman

Pagina 17

Remote Interface Reference 3 System-Related CommandsE364xA User’s and Service Guide 91System-Related CommandsDISPlay {OFF|ON}Turn the front panel disp

Pagina 18

3 Remote Interface Reference System-Related Commands92 E364xA User’s and Service GuideOUTPut?Query the output state of the power supply. The returned

Pagina 19 - List of Figures

Remote Interface Reference 3 System-Related CommandsE364xA User’s and Service Guide 93SYSTem:VERSion?Query the power supply to determine the present S

Pagina 20

3 Remote Interface Reference System-Related Commands94 E364xA User’s and Service Guide*RSTReset the power supply to its power- on state. Table 3- 4 s

Pagina 21 - List of Tables

Remote Interface Reference 3 State Storage CommandsE364xA User’s and Service Guide 95State Storage CommandsThe power supply has five storage locations

Pagina 22

3 Remote Interface Reference State Storage Commands96 E364xA User’s and Service GuideMEMory:STATe:NAME {1|2|3|4|5}, <quoted name>MEMory:STATe:N

Pagina 23 - Getting Started

Remote Interface Reference 3 Calibration CommandsE364xA User’s and Service Guide 97Calibration CommandsRefer to “Calibration” on page 58 for an overv

Pagina 24 - Introduction

XII E364xA User’s and Service Guide2 Operation and FeaturesOverview 32Constant Voltage Operation 34Front panel operation 34Remote inter

Pagina 25 - Front panel operations

3 Remote Interface Reference Calibration Commands98 E364xA User’s and Service GuideCALibration:CURRent:LEVel {MINimum|MIDdle|MAXimum}This command can

Pagina 26

Remote Interface Reference 3 Calibration CommandsE364xA User’s and Service Guide 99CALibration:VOLTage[:DATA] <numeric value>This command can on

Pagina 27

3 Remote Interface Reference Calibration Commands100 E364xA User’s and Service GuideCalibration example1 Enable the output of the power supply.OUTP O

Pagina 28 - Standard Shipped Items

Remote Interface Reference 3 Calibration CommandsE364xA User’s and Service Guide 10114 Record calibration information such as the next calibration due

Pagina 29 - Accessories

3 Remote Interface Reference Interface Configuration Commands102 E364xA User’s and Service GuideInterface Configuration CommandsSee also Chapter 2, “

Pagina 30 - Preparing the Power Supply

Remote Interface Reference 3 SCPI Status RegistersE364xA User’s and Service Guide 103SCPI Status RegistersAll SCPI instruments implement status regist

Pagina 31

3 Remote Interface Reference SCPI Status Registers104 E364xA User’s and Service GuideFigure 3-1 SCPI status systemBinary Weight20 = 121 = 222 = 423 =

Pagina 32 - Checking the output

Remote Interface Reference 3 SCPI Status RegistersE364xA User’s and Service Guide 105Questionable Status registerThe Questionable Status register prov

Pagina 33 - Current output check

3 Remote Interface Reference SCPI Status Registers106 E364xA User’s and Service GuideThe Questionable Status Enable register is cleared when you exec

Pagina 34 - Converting line voltage

Remote Interface Reference 3 SCPI Status RegistersE364xA User’s and Service Guide 107The Standard Event register is cleared when:• you execute the *CL

Pagina 35 - Replace the power-line fuse

E364xA User’s and Service Guide XIIIRS-232 configuration overview 54RS-232 data frame format 55Connection to a computer or terminal 55R

Pagina 36

3 Remote Interface Reference SCPI Status Registers108 E364xA User’s and Service GuideStatus Byte registerThe Status Byte summary register reports con

Pagina 37 - Adjusting the carrying handle

Remote Interface Reference 3 SCPI Status RegistersE364xA User’s and Service Guide 109The Status Byte enable register (request service) is cleared when

Pagina 38 - Front Rear (bottom view)

3 Remote Interface Reference SCPI Status Registers110 E364xA User’s and Service GuideUsing *STB? to read the Status ByteThe *STB? (Status Byte query

Pagina 39

Remote Interface Reference 3 SCPI Status RegistersE364xA User’s and Service Guide 111Using SRQ to interrupt the bus controller1 Send a device clear me

Pagina 40 - Product at a Glance

3 Remote Interface Reference SCPI Status Registers112 E364xA User’s and Service GuideUsing *OPC to signal when data is in the output bufferGenerally,

Pagina 41 - Getting Started 1

Remote Interface Reference 3 Status Reporting CommandsE364xA User’s and Service Guide 113Status Reporting CommandsRefer to Figure 3- 1 on page 104 for

Pagina 42

3 Remote Interface Reference Status Reporting Commands114 E364xA User’s and Service GuideSTATus:QUEStionable:ENABle?Query the Questionable Status Ena

Pagina 43 - Rear panel

Remote Interface Reference 3 Status Reporting CommandsE364xA User’s and Service Guide 115*PSC {0|1}This power- on status clear command clears the Stat

Pagina 44 - Display annunciators

3 Remote Interface Reference Halting an Output in Progress116 E364xA User’s and Service GuideHalting an Output in ProgressYou can send a device clear

Pagina 45

Remote Interface Reference 3 SCPI Conformance InformationE364xA User’s and Service Guide 117SCPI Conformance InformationThe power supply conforms to t

Pagina 46 - Output connections

XIV E364xA User’s and Service GuideAPPLy? 81Output Settings and Operation Commands 82Triggering 88Trigger source 88Triggering comm

Pagina 47 - Load consideration

3 Remote Interface Reference SCPI Conformance Information118 E364xA User’s and Service Guide[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude] {<vol

Pagina 48 - Reverse current loading

Remote Interface Reference 3 SCPI Conformance InformationE364xA User’s and Service Guide 119Device-specific commandsThe following commands are device-

Pagina 49

3 Remote Interface Reference IEEE-488 Conformance Information120 E364xA User’s and Service GuideIEEE-488 Conformance InformationDedicated hardware li

Pagina 50 - CV regulation

Remote Interface Reference 3 IEEE-488 Conformance InformationE364xA User’s and Service Guide 121IEEE-488.2 common commands*CLS*ESE <enable value>

Pagina 51 - Multiple loads

3 Remote Interface Reference IEEE-488 Conformance Information122 E364xA User’s and Service GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Pagina 52 - Operating the Power Supply

123E364xA Single Output DC Power SuppliesUser’s and Service GuideAgilent Technologies4Error MessagesOverview 124Execution Error Messages 126Self

Pagina 53 - Operation and Features

4 Error Messages Overview124 E364xA User’s and Service GuideOverviewErrors are retrieved in the first- in- first- out (FIFO) order. The first error r

Pagina 54

Error Messages 4 OverviewE364xA User’s and Service Guide 125Remote interface operationErrors have the following format (the error string may contain u

Pagina 55

4 Error Messages Execution Error Messages126 E364xA User’s and Service GuideExecution Error MessagesTable 4 - 1 Execution error messages -101 Invalid

Pagina 56 - Constant Voltage Operation

Error Messages 4 Execution Error MessagesE364xA User’s and Service Guide 127-113 Undefined headerA command was received that is not valid for this pow

Pagina 57

E364xA User’s and Service Guide XVAddressed commands 120IEEE-488.2 common commands 1214 Error MessagesOverview 124Front panel operation

Pagina 58 - Constant Current Operation

4 Error Messages Execution Error Messages128 E364xA User’s and Service Guide-138 Suffix not allowedA suffix was received following a numeric paramete

Pagina 59

Error Messages 4 Execution Error MessagesE364xA User’s and Service Guide 129-221 Settings conflictIndicates that a legal program data element was pars

Pagina 60

4 Error Messages Execution Error Messages130 E364xA User’s and Service Guide-440 Query UNTERMINATED after indefinite responseThe *IDN? command must b

Pagina 61 - RS-232 configuration

Error Messages 4 Self-Test Error MessagesE364xA User’s and Service Guide 131Self-Test Error MessagesThe following errors indicate failures that may oc

Pagina 62 - Front panel operation

4 Error Messages Self-Test Error Messages132 E364xA User’s and Service Guide608 Serial configuration readback failedThis test re-sends the last 3 byt

Pagina 63 - Recalling a stored state

Error Messages 4 Calibration Error MessagesE364xA User’s and Service Guide 133Calibration Error MessagesThe following errors indicate failures that ma

Pagina 64

4 Error Messages Calibration Error Messages134 E364xA User’s and Service Guide714 Bad OVP cal dataThe overvoltage protection calibration constant is

Pagina 65 - Checking the OVP operation

135E364xA Single Output DC Power SuppliesUser’s and Service GuideAgilent Technologies5Application ProgramsOverview 136Example Program for C and C++

Pagina 66

5 Application Programs Overview136 E364xA User’s and Service GuideOverviewThe application program examples in this chapter help you to develop progra

Pagina 67 - ±1 V (i.e., +1 V max during

Application Programs 5 Example Program for C and C++E364xA User’s and Service Guide 137Example Program for C and C++The following C programming exampl

Pagina 68

XVI E364xA User’s and Service GuideElectrical Specifications 164Supplemental Characteristics 1668 Service and MaintenanceOverview 170Op

Pagina 69 - Disabling the Output

5 Application Programs Example Program for C and C++138 E364xA User’s and Service Guidevoid OpenPort();void main(){double voltage; /* Value of vo

Pagina 70

Application Programs 5 Example Program for C and C++E364xA User’s and Service Guide 139void OpenPort(){char GPIB_Address[3];char COM_Address[2];char V

Pagina 71 - System-Related Operations

5 Application Programs Example Program for C and C++140 E364xA User’s and Service Guidestrcpy(pString,ReadBuffer);}}void ClosePort(){/* Close the com

Pagina 72 - Self-test

Application Programs 5 Example Program for Excel 97E364xA User’s and Service Guide 141Example Program for Excel 97This section contains the example pr

Pagina 73 - Firmware revision query

5 Application Programs Example Program for Excel 97142 E364xA User’s and Service GuideTo write an Excel macro:1 You must first open a module in Excel

Pagina 74 - SCPI language version

Application Programs 5 Example Program for Excel 97E364xA User’s and Service Guide 143Make any changes necessary to suit your application in the Diode

Pagina 75 - GPIB Interface Reference

5 Application Programs Example Program for Excel 97144 E364xA User’s and Service GuidePrivate Function OpenPort() Dim GPIB_Address As String Di

Pagina 76 - RS-232 Interface Reference

Application Programs 5 Example Program for Excel 97E364xA User’s and Service Guide 145Private Function ClosePort() ErrorStatus = viClose(power_supp

Pagina 77 - RS-232 data frame format

5 Application Programs Example Program for Excel 97146 E364xA User’s and Service GuideDeclaration for Windows 95/NT 4.0'************************

Pagina 78 - DB-25 serial connection

147E364xA Single Output DC Power SuppliesUser’s and Service GuideAgilent Technologies6TutorialOverview of the Power Supply Operation 148Output Char

Pagina 79 - RS-232 troubleshooting

E364xA User’s and Service Guide XVIIGeneral measurement techniques 185Electronic load 186Programming 186Constant Voltage (CV) Verificat

Pagina 80 - Calibration

6 Tutorial Overview of the Power Supply Operation148 E364xA User’s and Service GuideOverview of the Power Supply OperationThe basic design model for

Pagina 81 - To unsecure for calibration

Tutorial 6 Overview of the Power Supply OperationE364xA User’s and Service Guide 149This power supply has two ranges, allowing more voltage at a lower

Pagina 82 - To secure against calibration

6 Tutorial Output Characteristics150 E364xA User’s and Service GuideOutput CharacteristicsAn ideal constant voltage power supply would have a zero ou

Pagina 83 - To change the security code

Tutorial 6 Output CharacteristicsE364xA User’s and Service Guide 151The ideal constant current power supply exhibits an infinite output impedance at a

Pagina 84 - Calibration count

6 Tutorial Output Characteristics152 E364xA User’s and Service GuideFigure 6-5 Output characteristicsWhen the load RL is less than RC, the output cur

Pagina 85 - Calibration message

Tutorial 6 Output CharacteristicsE364xA User’s and Service Guide 153Unwanted signalsAn ideal power supply has a perfect DC output with no signals acro

Pagina 86

6 Tutorial Output Characteristics154 E364xA User’s and Service GuideFigure 6-6 Simplified diagram of the common mode and normal mode sources of noise

Pagina 87 - Remote Interface Reference

Tutorial 6 Extending the Voltage Range and Current RangeE364xA User’s and Service Guide 155Extending the Voltage Range and Current RangeThe power supp

Pagina 88 - SCPI Command Summary

6 Tutorial Extending the Voltage Range and Current Range156 E364xA User’s and Service GuideParallel connectionsTwo or more power supplies being capab

Pagina 89 - Remote Interface Reference 3

Tutorial 6 Remote ProgrammingE364xA User’s and Service Guide 157Remote ProgrammingDuring remote programming, a constant- voltage regulated power suppl

Pagina 90

XVIII E364xA User’s and Service GuideComponent locator diagram for the main board assembly — bottom 216Component locator diagram for the front pa

Pagina 91

6 Tutorial Remote Programming158 E364xA User’s and Service GuideWhen this exponential rise reaches the newly programmed voltage level, the constant v

Pagina 92

Tutorial 6 Remote ProgrammingE364xA User’s and Service Guide 159Since up- programming speed is aided by the conduction of the series regulating transi

Pagina 93

6 Tutorial Remote Programming160 E364xA User’s and Service GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Pagina 94

161E364xA Single Output DC Power SuppliesUser’s and Service GuideAgilent Technologies7Characteristics and SpecificationsPhysical Characteristics 16

Pagina 95 - Command separators

7 Characteristics and Specifications Physical Characteristics162 E364xA User’s and Service GuidePhysical CharacteristicsFigure 7-1 E364xA dimensionsT

Pagina 96 - Querying parameter settings

Characteristics and Specifications 7 Environmental CharacteristicsE364xA User’s and Service Guide 163Figure 7-2 E364xA dimensions for rack mountingEnv

Pagina 97 - SCPI parameter types

7 Characteristics and Specifications Electrical Specifications164 E364xA User’s and Service GuideElectrical SpecificationsTable 7 - 2 Electrical spec

Pagina 98 - String parameters

Characteristics and Specifications 7 Electrical SpecificationsE364xA User’s and Service Guide 165Load regulation±(% of output + offset)Voltage <0.0

Pagina 99 - Using the low-level commands

7 Characteristics and Specifications Supplemental Characteristics166 E364xA User’s and Service GuideSupplemental CharacteristicsTable 7 - 3 Supplemen

Pagina 100 - Selecting a trigger source

Characteristics and Specifications 7 Supplemental CharacteristicsE364xA User’s and Service Guide 167Output terminal isolation(maximum, from chassis gr

Pagina 101

E364xA User’s and Service Guide XIXList of FiguresFigure 1-1 Rear output terminals 5Figure 1-2 Line voltage selector (set for 115 Vac) 13Figur

Pagina 102

7 Characteristics and Specifications Supplemental Characteristics168 E364xA User’s and Service GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Pagina 103 - Using the APPLy Command

169E364xA Single Output DC Power SuppliesUser’s and Service GuideAgilent Technologies8Service and MaintenanceOverview 170Operating Checklist 171

Pagina 104 - CURRent? [MINimum

8 Service and Maintenance Overview170 E364xA User’s and Service GuideOverviewThe power supply must pass the complete self- test before calibration or

Pagina 105 - CURRent:TRIGgered

Service and Maintenance 8 Operating ChecklistE364xA User’s and Service Guide 171Operating ChecklistBefore returning your power supply to Agilent for s

Pagina 106 - VOLTage? [MINimum

8 Service and Maintenance Types of Service Available172 E364xA User’s and Service GuideTypes of Service AvailableIf your power supply fails within th

Pagina 107 - VOLTage:TRIGgered

Service and Maintenance 8 Repacking for ShipmentE364xA User’s and Service Guide 173Repacking for ShipmentIf your unit is to be shipped to Agilent for

Pagina 108

8 Service and Maintenance Electrostatic Discharge (ESD) Precautions174 E364xA User’s and Service GuideElectrostatic Discharge (ESD) PrecautionsAlmost

Pagina 109

Service and Maintenance 8 Troubleshooting HintsE364xA User’s and Service Guide 175Troubleshooting HintsThis section provides a brief checklist of comm

Pagina 110 - Triggering

8 Service and Maintenance Troubleshooting Hints176 E364xA User’s and Service GuideBias supplies problemsCheck that the input to the voltage regulator

Pagina 111 - Immediate triggering

Service and Maintenance 8 Self-Test ProceduresE364xA User’s and Service Guide 177Self-Test ProceduresPower-on self-testEach time the power supply is p

Pagina 112 - Triggering commands

II E364xA User’s and Service GuideNotices© Agilent Technologies, Inc. 1999–2013No part of this manual may be reproduced in any form or by any means (i

Pagina 113 - System-Related Commands

XX E364xA User’s and Service GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Pagina 114 - SYSTem:ERRor?

8 Service and Maintenance Self-Test Procedures178 E364xA User’s and Service Guide609[1]This test checks if the ADC hardware is functional. The main c

Pagina 115

Service and Maintenance 8 General DisassemblyE364xA User’s and Service Guide 179General DisassemblySELECTOR

Pagina 116

8 Service and Maintenance Recommended Test Equipment180 E364xA User’s and Service GuideRecommended Test EquipmentTable 8- 4 describes the test equipm

Pagina 117 - State Storage Commands

Service and Maintenance 8 Recommended Test EquipmentE364xA User’s and Service Guide 181Resistive loads (RL) • For E3640A: 2.7 Ω , 150 W/13.5 Ω , 150 W

Pagina 118

8 Service and Maintenance Test Considerations182 E364xA User’s and Service GuideTest ConsiderationsTo ensure proper operation of the power supply, ve

Pagina 119 - Calibration Commands

Service and Maintenance 8 Operation Verification and Performance TestsE364xA User’s and Service Guide 183Operation Verification and Performance TestsO

Pagina 120

8 Service and Maintenance Measurement Techniques184 E364xA User’s and Service GuideMeasurement TechniquesCommon test setupMost tests are performed at

Pagina 121 - {MINimum

Service and Maintenance 8 Measurement TechniquesE364xA User’s and Service Guide 185Current-monitoring resistorTo eliminate the output current measurem

Pagina 122 - Calibration example

8 Service and Maintenance Measurement Techniques186 E364xA User’s and Service GuideElectronic loadMany of the test procedures require the use of a va

Pagina 123

Service and Maintenance 8 Constant Voltage (CV) VerificationsE364xA User’s and Service Guide 187Constant Voltage (CV) VerificationsConstant voltage te

Pagina 124 - <Ctrl-C>

E364xA User’s and Service Guide XXIList of TablesTable 1-1 E364xA options 6Table 1-2 E364xA accessories 7Table 1-3 E364xA power-line fuse

Pagina 125 - SCPI Status Registers

8 Service and Maintenance Constant Voltage (CV) Verifications188 E364xA User’s and Service Guide1 Turn off the power supply and connect a digital vol

Pagina 126 - Figure 3-1 SCPI status system

Service and Maintenance 8 Constant Voltage (CV) VerificationsE364xA User’s and Service Guide 189CV load effect (load regulation)This test measures the

Pagina 127 - Questionable Status register

8 Service and Maintenance Constant Voltage (CV) Verifications190 E364xA User’s and Service GuideCV source effect (line regulation)This test measures

Pagina 128 - Standard Event register

Service and Maintenance 8 Constant Voltage (CV) VerificationsE364xA User’s and Service Guide 191CV PARD (ripple and noise)Periodic and random deviatio

Pagina 129 - Bit Decimal value Definition

8 Service and Maintenance Constant Voltage (CV) Verifications192 E364xA User’s and Service Guide1 Turn off the power supply and connect the output to

Pagina 130 - Status Byte register

Service and Maintenance 8 Constant Voltage (CV) VerificationsE364xA User’s and Service Guide 193Load transient response timeThis test measures the tim

Pagina 131

8 Service and Maintenance Constant Voltage (CV) Verifications194 E364xA User’s and Service GuideFigure 8-4 Transient response time

Pagina 132

Service and Maintenance 8 Constant Current (CC) VerificationsE364xA User’s and Service Guide 195Constant Current (CC) VerificationsConstant current te

Pagina 133

8 Service and Maintenance Constant Current (CC) Verifications196 E364xA User’s and Service Guide3 Program the output voltage to the full- scale rated

Pagina 134

Service and Maintenance 8 Constant Current (CC) VerificationsE364xA User’s and Service Guide 197CC load effect (load regulation)This test measures the

Pagina 135 - Status Reporting Commands

XXII E364xA User’s and Service GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Pagina 136

8 Service and Maintenance Constant Current (CC) Verifications198 E364xA User’s and Service GuideCC source effect (line regulation)This test measures

Pagina 137

Service and Maintenance 8 Constant Current (CC) VerificationsE364xA User’s and Service Guide 199CC PARD (ripple and noise)Periodic and random deviatio

Pagina 138 - Halting an Output in Progress

8 Service and Maintenance Constant Current (CC) Verifications200 E364xA User’s and Service GuideFigure 8-5 CC PARD (ripple and noise) connections1 Tu

Pagina 139 - SCPI Conformance Information

Service and Maintenance 8 Common Mode Current NoiseE364xA User’s and Service Guide 201Common Mode Current NoiseThe common mode current is the AC curre

Pagina 140

8 Service and Maintenance Performance Test Record202 E364xA User’s and Service GuidePerformance Test RecordTable 8 - 6 CV performance test recordTest

Pagina 141 - Device-specific commands

Service and Maintenance 8 Performance Test RecordE364xA User’s and Service Guide 203Table 8 - 7 CC performance test record Test description Model Actu

Pagina 142 - Addressed commands

8 Service and Maintenance Performance Test Record204 E364xA User’s and Service GuideCC source effect (line regulation) E3640A Maximum change: <0.5

Pagina 143 - IEEE-488.2 common commands

Service and Maintenance 8 Calibration ReferenceE364xA User’s and Service Guide 205Calibration ReferenceBefore you calibrate the power supply, you must

Pagina 144

8 Service and Maintenance Calibration Reference206 E364xA User’s and Service GuideTo unsecure the power supply without the security codeTo unsecure t

Pagina 145 - Error Messages

Service and Maintenance 8 General Calibration or Adjustment ProcedureE364xA User’s and Service Guide 207General Calibration or Adjustment ProcedureThe

Pagina 146 - Overview

1E364xA Single Output DC Power SuppliesUser’s and Service GuideAgilent Technologies1Getting StartedIntroduction 2Standard Shipped Items 6Prepari

Pagina 147 - Remote interface operation

8 Service and Maintenance General Calibration or Adjustment Procedure208 E364xA User’s and Service GuideFront panel voltage and current calibrationIn

Pagina 148 - Execution Error Messages

Service and Maintenance 8 General Calibration or Adjustment ProcedureE364xA User’s and Service Guide 2096 Enter the reading you obtained from the DVM

Pagina 149 - Error Messages 4

8 Service and Maintenance General Calibration or Adjustment Procedure210 E364xA User’s and Service Guide12 Enter the computed value (DVM reading divi

Pagina 150

Service and Maintenance 8 Calibration RecordE364xA User’s and Service Guide 211Calibration RecordTable 8 - 9 Calibration record Step Calibration descr

Pagina 151

8 Service and Maintenance Calibration Error Messages212 E364xA User’s and Service GuideCalibration Error MessagesTable 8- 10 shows the abbreviated li

Pagina 152

Service and Maintenance 8 Calibration Error MessagesE364xA User’s and Service Guide 213740 Cal checksum failed, secure state741 Cal checksum failed, s

Pagina 153 - Self-Test Error Messages

8 Service and Maintenance Calibration Error Messages214 E364xA User’s and Service GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Pagina 154

Service and Maintenance 8 Component Locator DiagramE364xA User’s and Service Guide 215Component Locator DiagramComponent locator diagram for the main

Pagina 155 - Calibration Error Messages

8 Service and Maintenance Component Locator Diagram216 E364xA User’s and Service GuideComponent locator diagram for the main board assembly — bottom

Pagina 156

Service and Maintenance 8 Component Locator DiagramE364xA User’s and Service Guide 217Component locator diagram for the front panel

Pagina 157 - Application Programs

1Getting Started Introduction2 E364xA User’s and Service GuideIntroductionThe Agilent E3640A/E3641A (30 W), E3642A/E3643A (50 W), and E3644A/E3645A (

Pagina 158

8 Service and Maintenance Component Locator Diagram218 E364xA User’s and Service GuideComponent locator diagram for the main board assembly — top (se

Pagina 159 - Example Program for C and C++

Service and Maintenance 8 Component Locator DiagramE364xA User’s and Service Guide 219Component locator diagram for the main board assembly — bottom (

Pagina 160

8 Service and Maintenance Component Locator Diagram220 E364xA User’s and Service GuideComponent locator diagram for the front panel (serial MY53xx6xx

Pagina 161 - Application Programs 5

© Agilent Technologies, Inc. 1999–2013Tenth Edition, August 6, 2013E3640-90001www.agilent.comAgilent TechnologiesContact usTo obtain service, warranty

Pagina 162 - End of program

Getting Started 1 IntroductionE364xA User’s and Service Guide 3The E364xA power supplies feature a combination of programming capabilities and linear

Pagina 163 - Example Program for Excel 97

1Getting Started Introduction4 E364xA User’s and Service Guide• Viewing the calibration message or system firmware revision• Calibrating the power su

Pagina 164

Getting Started 1 IntroductionE364xA User’s and Service Guide 5Figure 1-1 Rear output terminals1 Float voltage ±60 Vdc Max to (shorting conductors w

Pagina 165 - Diode macro

1Getting Started Standard Shipped Items6 E364xA User’s and Service GuideStandard Shipped ItemsVerify that you have received the following items in th

Pagina 166

Getting Started 1 Standard Shipped ItemsE364xA User’s and Service Guide 7AccessoriesThe accessories listed below may be ordered from your local Agilen

Pagina 167 - Declaration for Windows 3.1

E364xA User’s and Service Guide IIISafety SymbolsThe following symbols on the instrument and in the documentation indicate precautions which must be t

Pagina 168

1Getting Started Preparing the Power Supply8 E364xA User’s and Service GuidePreparing the Power SupplyChecking the power supply1 Check the shipped it

Pagina 169 - Tutorial

Getting Started 1 Preparing the Power SupplyE364xA User’s and Service Guide 9Connecting power to the power supplyIf the power supply does not turn onU

Pagina 170

1Getting Started Preparing the Power Supply10 E364xA User’s and Service GuideChecking the outputThe following procedures ensure that the power supply

Pagina 171

Getting Started 1 Preparing the Power SupplyE364xA User’s and Service Guide 11Current output checkThe following steps check the basic current function

Pagina 172 - Output Characteristics

1Getting Started Preparing the Power Supply12 E364xA User’s and Service GuideConverting line voltageLine voltage conversion is accomplished by adjust

Pagina 173

Getting Started 1 Preparing the Power SupplyE364xA User’s and Service Guide 13Figure 1-2 Line voltage selector (set for 115 Vac)Replace the power-line

Pagina 174 - Unregulated state

1Getting Started Preparing the Power Supply14 E364xA User’s and Service Guide2 Remove the fuse- holder from the assembly.3 Replace with the correct f

Pagina 175 - Unwanted signals

Getting Started 1 Preparing the Power SupplyE364xA User’s and Service Guide 15Adjusting the carrying handleTo adjust the position, grasp the handle by

Pagina 176

1Getting Started Preparing the Power Supply16 E364xA User’s and Service GuideRack-mounting the power supplyYou can mount the power supply in a standa

Pagina 177 - Series connections

Getting Started 1 Preparing the Power SupplyE364xA User’s and Service Guide 173 To rack- mount a single instrument, order the adapter kit (5063- 9240)

Pagina 178 - Parallel connections

IV E364xA User’s and Service GuideSafety ConsiderationsRead the information below before using this instrument. The following general safety precautio

Pagina 179 - Remote Programming

1Getting Started Product at a Glance18 E364xA User’s and Service GuideProduct at a GlanceFront panelFigure 1-3 Front panel outlookTable 1 - 4 Front p

Pagina 180

Getting Started 1 Product at a GlanceE364xA User’s and Service Guide 194 Display limit key Show the voltage and current limit values on the display an

Pagina 181

1Getting Started Product at a Glance20 E364xA User’s and Service GuideVoltage and current limit settingsYou can set the voltage and current limit val

Pagina 182

Getting Started 1 Product at a GlanceE364xA User’s and Service Guide 21Rear panelFigure 1-5 Rear panel outlookNOTEThe supplier code of the C-Tick for

Pagina 183 - Agilent Technologies

1Getting Started Product at a Glance22 E364xA User’s and Service GuideUse the front panel key to:• Select the GPIB or RS- 232 interface.• Set the G

Pagina 184 - Physical Characteristics

Getting Started 1 Product at a GlanceE364xA User’s and Service Guide 23OVP The overvoltage protection function is enabled when the OVP annunciator tur

Pagina 185 - Environmental Characteristics

1Getting Started Output connections24 E364xA User’s and Service GuideOutput connectionsFront panel binding posts are available to connect load wires

Pagina 186 - Electrical Specifications

Getting Started 1 Output connectionsE364xA User’s and Service Guide 25Voltage dropsThe load wires must also be large enough to avoid excessive voltage

Pagina 187

1Getting Started Output connections26 E364xA User’s and Service GuideInductive loadingInductive loads present no loop stability problems in the const

Pagina 188 - Supplemental Characteristics

Getting Started 1 Output connectionsE364xA User’s and Service Guide 27Remote voltage sensing connectionsRemote voltage sensing is used to maintain reg

Pagina 189

E364xA User’s and Service Guide VWARNING• Do not use MAINS supply cords by inadequately RATED cord. Always use the MAINS supply cord provided by the m

Pagina 190

1Getting Started Output connections28 E364xA User’s and Service GuideFigure 1-8 Local sensing connectionsStabilityUsing remote sensing under certain

Pagina 191 - Service and Maintenance

Getting Started 1 Output connectionsE364xA User’s and Service Guide 29Output ratingThe rated output voltage and current specifications in Chapter 7 ap

Pagina 192

1Getting Started Operating the Power Supply30 E364xA User’s and Service GuideOperating the Power SupplyCoolingThe power supply can operate at the rat

Pagina 193 - Operating Checklist

31E364xA Single Output DC Power SuppliesUser’s and Service GuideAgilent Technologies2Operation and FeaturesOverview 32Constant Voltage Operation

Pagina 194 - Types of Service Available

2 Operation and Features Overview32 E364xA User’s and Service GuideOverviewThe following section provides an overview of the front panel keys before

Pagina 195 - Repacking for Shipment

Operation and Features 2 OverviewE364xA User’s and Service Guide 33• The display provides the present operating status of the power supply with annunc

Pagina 196 - Replacing the Power-Line Fuse

2 Operation and Features Constant Voltage Operation34 E364xA User’s and Service GuideConstant Voltage OperationTo set up the power supply for constan

Pagina 197 - Troubleshooting Hints

Operation and Features 2 Constant Voltage OperationE364xA User’s and Service Guide 354 Adjust the knob for the desired current limit.[1]Check that the

Pagina 198 - Bias supplies problems

2 Operation and Features Constant Current Operation36 E364xA User’s and Service GuideRemote interface operationConstant Current OperationTo set up th

Pagina 199 - Self-Test Procedures

Operation and Features 2 Constant Current OperationE364xA User’s and Service Guide 374 Adjust the knob for the desired voltage limit.[1]Check that the

Pagina 200

VI E364xA User’s and Service GuideSafety and EMC RequirementsThis power supply is designed to comply with the following safety and Electromagnetic Com

Pagina 201 - General Disassembly

2 Operation and Features Configuring the Remote Interface38 E364xA User’s and Service GuideRemote interface operationConfiguring the Remote Interface

Pagina 202 - Recommended Test Equipment

Operation and Features 2 Configuring the Remote InterfaceE364xA User’s and Service Guide 39GPIB configuration1 Turn on the remote configuration mode.G

Pagina 203 - Ω , 300 W/46.2 Ω

2 Operation and Features Storing and Recalling Operating States40 E364xA User’s and Service Guide4 Select the parity and number of stop bits.Select o

Pagina 204 - Test Considerations

Operation and Features 2 Storing and Recalling Operating StatesE364xA User’s and Service Guide 412 Turn on the storage mode.STORE STATEFrom the front

Pagina 205 - Performance tests

2 Operation and Features Programming the Overvoltage Protection42 E364xA User’s and Service GuideRemote interface operationUse the following commands

Pagina 206 - Measurement Techniques

Operation and Features 2 Programming the Overvoltage ProtectionE364xA User’s and Service Guide 432 Enter the OVP menu and set the desired trip level.L

Pagina 207 - Current-monitoring resistor

2 Operation and Features Programming the Overvoltage Protection44 E364xA User’s and Service Guide• By adjusting the output voltage leveli Lower the o

Pagina 208 - Programming

Operation and Features 2 Programming the Overvoltage ProtectionE364xA User’s and Service Guide 45Figure 2-1 Recommended protection circuit for battery

Pagina 209 - Constant voltage test setup

2 Operation and Features Programming the Overvoltage Protection46 E364xA User’s and Service Guideany reverse voltage and current flow to the DUT. Not

Pagina 210

Operation and Features 2 Disabling the OutputE364xA User’s and Service Guide 47Disabling the OutputThe output of the power supply can be disabled or e

Pagina 211

E364xA User’s and Service Guide VIIRegulatory MarkingsThe CE mark is a registered trademarkof the European Community. This CEmark shows that the produ

Pagina 212

2 Operation and Features Disabling the Output48 E364xA User’s and Service GuideDisconnecting the output using an external relayTo disconnect the outp

Pagina 213 - CV PARD (ripple and noise)

Operation and Features 2 System-Related OperationsE364xA User’s and Service Guide 49System-Related OperationsThis section gives information on system-

Pagina 214

2 Operation and Features System-Related Operations50 E364xA User’s and Service GuideFront panel operationSTORE STATE, NAME STATE, EXITTo reset the po

Pagina 215 - Load transient response time

Operation and Features 2 System-Related OperationsE364xA User’s and Service Guide 51If the complete self- test is successful, PASS is displayed on the

Pagina 216

2 Operation and Features System-Related Operations52 E364xA User’s and Service GuideFront panel operationREV X.X-Y.Y-Z.ZPress twice to read the sys

Pagina 217 - Constant current test setup

Operation and Features 2 GPIB Interface ReferenceE364xA User’s and Service Guide 53GPIB Interface ReferenceThe GPIB connector on the rear panel connec

Pagina 218

2 Operation and Features RS-232 Interface Reference54 E364xA User’s and Service GuideRS-232 Interface ReferenceThe power supply can be connected to t

Pagina 219

Operation and Features 2 RS-232 Interface ReferenceE364xA User’s and Service Guide 55RS-232 data frame formatA character frame consists of all the tra

Pagina 220

2 Operation and Features RS-232 Interface Reference56 E364xA User’s and Service GuideThe cable and adapter diagrams as shown in Figure 2- 3 and Figur

Pagina 221 - CC PARD (ripple and noise)

Operation and Features 2 RS-232 Interface ReferenceE364xA User’s and Service Guide 57Figure 2-4 DB-25 serial connectionRS-232 troubleshootingHere are

Pagina 222

VIII E364xA User’s and Service GuideWaste Electrical and Electronic Equipment (WEEE) Directive 2002/96/ECThis instrument complies with the WEEE Direct

Pagina 223 - Common Mode Current Noise

2 Operation and Features Calibration58 E364xA User’s and Service GuideCalibrationThis section gives an overview of the calibration features of the po

Pagina 224 - Performance Test Record

Operation and Features 2 CalibrationE364xA User’s and Service Guide 59To unsecure for calibrationYou can unsecure the power supply either from the fro

Pagina 225

2 Operation and Features Calibration60 E364xA User’s and Service GuideYou will see the above message if the security code is correct, and the CAL MOD

Pagina 226

Operation and Features 2 CalibrationE364xA User’s and Service Guide 613 Save the change and exit the menu.securedThe secured setting is stored in non-

Pagina 227 - Calibration Reference

2 Operation and Features Calibration62 E364xA User’s and Service GuideRemote interface operationTo change the security code, first unsecure the power

Pagina 228

Operation and Features 2 CalibrationE364xA User’s and Service Guide 63Calibration messageThe power supply allows you to store one message in calibrati

Pagina 229

2 Operation and Features Calibration64 E364xA User’s and Service GuideTHIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.

Pagina 230 - Voltage and OVP calibration

65E364xA Single Output DC Power SuppliesUser’s and Service GuideAgilent Technologies3Remote Interface ReferenceSCPI Command Summary 66Introduction

Pagina 231 - Current calibration

3 Remote Interface Reference SCPI Command Summary66 E364xA User’s and Service GuideSCPI Command SummaryThis section summarizes the Standard Commands

Pagina 232

Remote Interface Reference 3 SCPI Command SummaryE364xA User’s and Service Guide 67Table 3 - 1 SCPI command summary Output Settings and Operation Comm

Pagina 233 - Calibration Record

E364xA User’s and Service Guide IXDeclaration of Conformity (DoC)The Declaration of Conformity (DoC) for this instrument is available on the Agilent W

Pagina 234

3 Remote Interface Reference SCPI Command Summary68 E364xA User’s and Service GuideSystem-Related CommandsDISPlay[:WINDow][:STATe] {OFF|ON}[:STATe]?:

Pagina 235

Remote Interface Reference 3 SCPI Command SummaryE364xA User’s and Service Guide 69Interface Configuration CommandsSYSTem:INTerface {GPIB|RS232}:LOCal

Pagina 236

3 Remote Interface Reference SCPI Command Summary70 E364xA User’s and Service GuideIEEE-488.2 common commands*CLS*ESR?*ESE <enable value>*ESE?*

Pagina 237 - Component Locator Diagram

Remote Interface Reference 3 Introduction to the SCPI LanguageE364xA User’s and Service Guide 71Introduction to the SCPI LanguageStandard Commands for

Pagina 238

3 Remote Interface Reference Introduction to the SCPI Language72 E364xA User’s and Service GuideCommand format used in this manualThe format used to

Pagina 239

Remote Interface Reference 3 Introduction to the SCPI LanguageE364xA User’s and Service Guide 73Some portions of commands are enclosed in square brack

Pagina 240

3 Remote Interface Reference Introduction to the SCPI Language74 E364xA User’s and Service GuideUsing the MIN and MAX parametersYou can substitute MI

Pagina 241

Remote Interface Reference 3 Introduction to the SCPI LanguageE364xA User’s and Service Guide 75SCPI command terminatorsA command string sent to the p

Pagina 242

3 Remote Interface Reference Introduction to the SCPI Language76 E364xA User’s and Service GuideYou can also send engineering unit suffixes (V, A, or

Pagina 243

Remote Interface Reference 3 Simplified Programming OverviewE364xA User’s and Service Guide 77Simplified Programming OverviewThis section gives an ove

Commenti su questo manuale

Nessun commento