AGILENT 35670A
Supplemental Operator’s Guide
3
Section 3 : Measuring with Transducers
The AGILENT 35670A can be used with a broad range of transducers. Transducers
can use an external preamplifier to convert the raw signal into a voltage that is
compatible with the AGILENT 35670A. Some transducers have internal circuitry
which provides preamplification, however these internal circuits must be powered
externally. The AGILENT 35670A can provide the necessary constant-current
supply for transducers that are of type ICP, Isotron, Piezotron, DelaTron, Low
Impedance, etc.
Using ICP-Type Transducers with the AGILENT 35670A
To set up Channel 1 for an ICP-type transducer:
Press the [Input] hardkey
Press [FRONT END CH1 SETUP] softkey (F7).
Press [ICP SUPLY ON OFF] softkey (F8) until ON is highlighted.
Note that the analyzer automatically switches the front end to AC Coupling in order
to reject the large DC signal that is generated by the constant-current supply.
To set up Channel 2 for an ICP transducer:
Press the [Input] hardkey
Press [CHANNEL 1 2 34] softkey (F1) until 2 is highlighted.
Press [FRONT END CH2 SETUP] softkey (F7).
Press [ICP SUPLY ON OFF] softkey (F8) until ON is highlighted.
For AGILENT 35670A analyzers with four channels, these same procedures can be
repeated for Channels 3 and 4.
Using Transducers with External Preamplifiers
No special front end setup is required to use transducers with external preamplifiers
except if the preamplifier’s DC component is too high, resulting in a loss of dynamic
range. This can be easily minimized by switching to AC coupling as follows:
Press the [Input] hardkey
Press [CHANNEL 1 234] softkey (F1) until 1 is highlighted.
Press [FRONT END CH1 SETUP] softkey (F7).
Press [COUPLING AC DC] softkey (F5) until AC is highlighted.
A transducer with an external preamplifier will convert mechanical units (EU) to
volts. Care must be taken to observe gain settings on the external preamplifier,
because these gain settings directly affect the resulting transducer sensitivity.
Vedere la pagina 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 81 82

Commenti su questo manuale

Nessun commento

ASCOM OFFICE 130PRO manuals

Owner’s manuals and user’s guides for Telephones ASCOM OFFICE 130PRO.
We providing 3 pdf manuals ASCOM OFFICE 130PRO for download free by document types: Operations Instructions, User Manual, User's Guide






More products and manuals for Telephones ASCOM

Models Document Type
OFFICE 25 Operations Instructions   ASCOM OFFICE 25 Operating instructions, 52 pages
Eurit 33 Plus User Manual   Ascom Eurit 33 / 33 plus, 100 pages
Eurit 20 User Manual   ascom Eurit 30, 35 pages
OFFICE 10 User Manual Ascotel Office Terminals by ascom, 68 pages
Eurit 33 Plus Operations Instructions   ASCOM Eurit 33 Plus Operating instructions [en] , 100 pages
D81 - User Manual   ASCOM D81 - User manual [en] [es] , 120 pages
21 User Manual   ASCOM 21 User manual, 57 pages
I62 - User Manual   ASCOM I62 - User manual, 22 pages
i75 VoWiFi User Manual   Application Note for Configuring the Ascom wireless i75 VoWiFi, 24 pages
TD 92582GB User Manual   ASCOM TD 92582GB User manual, 48 pages
i75 VoWiFi User Manual   Application Note for Configuring the Ascom wireless i75 VoWiFi [en] , 26 pages
TD 92582GB User Manual   ASCOM TD 92582GB User manual, 23 pages
21 User Manual   ASCOM 21 User manual, 108 pages
Eurit 20 User Manual   ascom Eurit 20, 26 pages
OfficeT User Manual   Application Note for Configuring the Ascom Wireless IP, 22 pages
Eurit 33 Plus User Manual   ASCOM Eurit 33 Plus User manual, 105 pages
TD 92582GB User Manual   ASCOM TD 92582GB User manual, 32 pages
I62 - User Manual   ASCOM I62 - User manual, 78 pages
d41 DECT User Manual   Application Note for Configuring the Ascom Wireless IP, 27 pages
Avena 122 plus User's Guide    ASCOM Avena 122 plus User guide, 74 pages