Relay Multiplexer Command Reference 49
Parameters Parameter Types. The following table contains explanations and examples of
parameter types you might see later in this chapter.
Optional Parameters. Parameters shown within square brackets ([]) are optional
parameters. (Note that the brackets are not part of the command and are not sent to
the instrument.) If you do not specify a value for an optional parameter, the
instrument chooses a default value. For example, consider the
ARM:COUNt? [<MIN|MAX>]
command. If you send the command without
specifying a parameter, the present
ARM:COUNt value is returned. If you send the
MIN parameter, the command returns the minimum count available. If you send the
MAX parameter, the command returns the maximum count available. Be sure to
place a space between the command and the parameter.
Linking
Commands
Linking IEEE 488.2 Common Commands with SCPI Commands. Use a
semicolon between the commands. For example:
*RST;OUTP ON or TRIG:SOUR HOLD;*TRG
Linking Multiple SCPI Commands. Use both a semicolon and a colon between the
commands. For example:
ARM COUN 1;:TRIG:SOUR EXT
SCPI Command Reference
This section describes the Standard Commands for Programmable Instruments
(SCPI) commands for the multiplexer modules. Commands are listed alphabetically
by subsystem and also within each subsystem.
Parameter
Type Explanations and Examples
Numeric Accepts all commonly used decimal representations of numbers
including optional signs, decimal points, and scientific notation.
123, 123E2, -123, -1.23E2, .123, 1.23E-2, 1.23000E-01. Special
cases include MIN, MAX, and INF.
Boolean Represents a single binary condition that is either true or false.
ON, OFF, 1, 0.
Discrete Selects from a finite number of values. These parameters use
mnemonics to represent each valid setting.
An example is the TRIGger:SOURce <
source> command
where source can be BUS, EXT, HOLD, or IMM.
Vedere la pagina 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 92 93

Commenti su questo manuale

Nessun commento

ASCOM OFFICE 130PRO manuals

Owner’s manuals and user’s guides for Telephones ASCOM OFFICE 130PRO.
We providing 3 pdf manuals ASCOM OFFICE 130PRO for download free by document types: Operations Instructions, User Manual, User's Guide






More products and manuals for Telephones ASCOM

Models Document Type
OFFICE 25 Operations Instructions   ASCOM OFFICE 25 Operating instructions, 52 pages
Eurit 33 Plus User Manual   Ascom Eurit 33 / 33 plus, 100 pages
Eurit 20 User Manual   ascom Eurit 30, 35 pages
OFFICE 10 User Manual Ascotel Office Terminals by ascom, 68 pages
Eurit 33 Plus Operations Instructions   ASCOM Eurit 33 Plus Operating instructions [en] , 100 pages
D81 - User Manual   ASCOM D81 - User manual [en] [es] , 120 pages
21 User Manual   ASCOM 21 User manual, 57 pages
I62 - User Manual   ASCOM I62 - User manual, 22 pages
i75 VoWiFi User Manual   Application Note for Configuring the Ascom wireless i75 VoWiFi, 24 pages
TD 92582GB User Manual   ASCOM TD 92582GB User manual, 48 pages
i75 VoWiFi User Manual   Application Note for Configuring the Ascom wireless i75 VoWiFi [en] , 26 pages
TD 92582GB User Manual   ASCOM TD 92582GB User manual, 23 pages
21 User Manual   ASCOM 21 User manual, 108 pages
Eurit 20 User Manual   ascom Eurit 20, 26 pages
OfficeT User Manual   Application Note for Configuring the Ascom Wireless IP, 22 pages
Eurit 33 Plus User Manual   ASCOM Eurit 33 Plus User manual, 105 pages
TD 92582GB User Manual   ASCOM TD 92582GB User manual, 32 pages
I62 - User Manual   ASCOM I62 - User manual, 78 pages
d41 DECT User Manual   Application Note for Configuring the Ascom Wireless IP, 27 pages
Avena 122 plus User's Guide    ASCOM Avena 122 plus User guide, 74 pages