Agilent Technologies C-Size VXIbus Systems Manuale Utente Pagina 123

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 178
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 122
Step-6 : Install Backplane Connector Shields
For conformance with the following European EMC Standards:
CISPR 11:1990/EN 55011 (1991): Group 1 Class A
IEC 801-2:1991/EN 50082-1 (1992): 4 kVCD, 8 kVAD
IEC 801-3:1984/EN 50082-1 (1992): 3 V/m
IEC 801-4:1988/EN 50082-1 (1992): 1 kV
Some Agilent VXI modules ship with a backplane connector shield kit. This
kit includes:
Quantity Description Part Number
2 connector shields E1400-80601
4 TORX screws 0624-0702
If you have a module which shipped with this kit and which must conform
to these standards, install the shields as shown in Figure 4-6. On the Agilent
E1401A mainframe, it may be necessary to temporarily remove the plastic
slot guide in order to install the bottom screw on the bottom shield.
Backplane
Connector
Shields
Mainframe Backplane
Figure 4-6. Installing the Backplane Connector Shields
C-Size Configuration Guide Configure and Install Instruments 4-15
Vedere la pagina 122
1 2 ... 118 119 120 121 122 123 124 125 126 127 128 ... 177 178

Commenti su questo manuale

Nessun commento