386 VEE User’s Guide
10 Test Sequencing Chapter
Figure 214 The noisyWv UserObject (Panel)
3 Select Device Sequencer and place it left- center of Main.
Add a data input terminal and name it mask.
4 Click the transaction bar to get the Sequence Transaction
dialog box. Change fields as follows:
test1 will get a result from noisyWv() and test it against the
limit value at the input terminal named mask. If the noisy
wave is less than or equal to the mask at all points, it will
pass. Otherwise, it will fail.
Table 4 3 Sequence Transaction Dialog Box
Field Description
FUNCTION Type in noisyWv().
RANGE Click and select LIMIT from the pop-up menu. Leave the
<=, and the LIMIT terminal name field type mask. All of
the other defaults are fine, so click
OK.