Agilent-technologies 3499A/B/C Manuale Utente

Navigare online o scaricare Manuale Utente per Accessori per computer Agilent-technologies 3499A/B/C. Agilent Technologies 3499A/B/C User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 20
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
How your 3499A/B/C Test System
Benefits From Upgrading to the New
34980A Switch/Measure/Control System
Application Note
This application note will describe
differences and advantages of the
new 34980A as compared to the
3499A/B/C. The 34980A
Switch/Measure System masters
switching, measurement, and
control features by offering a
superior selection of switch
topologies and system control
features. A state-of-the-art DMM
has been integrated into the
34980A mainframe providing a
wide variety of measure capability.
The 34980A mainframe also
includes standard PC connections
and instrument control options for
your ease of use.
Discover the detailed advantages of
upgrading your test system using
the 34980A in this document.
Measurements
One of the advantages of the new
34980A is its ability to make
highly accurate test system
measurements. The integration of
a high-speed DMM into the
mainframe enhances the 34980A
switch and control system by
providing voltage, current,
temperature, frequency, and
resistance measurements without
using any of the mainframe’s
available eight slots. The DMM
conveniently generates
measurement results in selectable
engineering units. Eleven
different types of measurements
can be made and are listed on the
page 2. The 34980A time-stamped
measurement data can be stored
or displayed and analyzed as the
measurements are acquired. The
34980A also has configurable
High/Low limits on each channel
that activate an alarm if the input
signals are out of the set range.
The 34980A’s integrated DMM
saves you time and money by
reducing the number of individual
instruments required, and
additional cabling for
measurements and triggering. In
comparison, the 3499A/B/C
switch requires an external DMM
or other measurement instrument
as well as additional wiring to
provide the same functionality.
Add functionality, streamline your test
programs, and reduce the physical test
system size by upgrading from your
3499A/B/C to the new 34980A
Multifunction Switch/Measure Unit.
34980A Mainframe, plug-in modules and terminal cards
Vedere la pagina 0
1 2 3 4 5 6 ... 19 20

Sommario

Pagina 1 - Application Note

How your 3499A/B/C Test SystemBenefits From Upgrading to the New34980A Switch/Measure/Control SystemApplication NoteThis application note will describ

Pagina 2 - Capabilities

10Switch and MeasurementConnectionsMost often, test systems must beflexible enough to be easily movedto a new location or modified fordifferent device

Pagina 3 - Benefits of the new 34980A

11SummaryAlthough the 3499A/B/CSwitch/Control system has been agreat addition to many testsystems, the new 34980A nowoffers an even better moduleselec

Pagina 4

12Appendix A – Command Reference/Comparison34980A CommandsABORtCALCulate:AVERage:AVERage?:AVERage:CLEar:AVERage:COUNt?:AVERage: MAXimum?:AVERage:MAXim

Pagina 5 - (Programming)

13:CURRent:AC:CURRent[:DC]:DIGital:STATe:DIGital:WIDTh:FREQuency:FRESistance:PERiod:RESistance:TEMPerature:TOTalize[:VOLTage]:AC[:VOLTage][:DC]CONFigu

Pagina 6

14:CURRent:AC?:CURRent[:DC]?:DIGital[:<width>]?:DIGital[:BYTE]:BIT?:FREQuency?FRESistance?:PERiod?:RESistance?:TEMPerature?:TOTalize?[:VOLTage]:

Pagina 7

15:SCAN:SCAN:ADD:SCAN:REMove:SCAN:SIZE?SAMPle:COUNt:COUNt?SENSe:CURRent:AC:BANDwidth:BANDwidth?:RANGe:RANGe?:RANGe:AUTO:RANGe:AUTO?:CURRent[:DC]:APERt

Pagina 8 - Scan Feature

16:RANGe:AUTO?:RESolution:RESolution?:ZERO:AUTO:FUNCtion:FUNCtion?:PERiod:APERture:PERiod:VOLTage:RANGe:VOLTage:RANGe?:VOLTage:RANGe:AUTO:VOLTage:RANG

Pagina 9 - Stored State Feature

17[:DC]:NPLC?[:DC]:RANGe[:DC]:RANGe?[:DC]:RANGe:AUTO[:DC]:RANGe:AUTO?[:DC]:RESolution[:DC]RESolution[:DC]:ZERO:AUTO[:DC]:ZERO:AUTO?SOURce:CURRent[:LEV

Pagina 10 - Connections

18:ALARm:ENABle?:ALARm[:EVENt]?:MODule:ENABle:MODule:EVENt?:MODule:SLOT[n]:CONDition?:MODule:SLOT[n]:ENABle:MODule:SLOT[n][:EVENt]?:OPERation:CONDitio

Pagina 11

19:TIME?:TIME:SCAN?:VERSion?TRACe:CATalog?[:DATA][:DATA]:DAC[:DATA]:FUNCtion:DELete:ALL:DELete[:NAME]:FREE?:POINts?TRIGger:COUnt:COUNt?:DELay:DELay?:D

Pagina 12 - 3499A/B/C Commands

2List of 34980A MeasurementCapabilities• Temperature measured withThermocouples, RTDs andThermistors• DC and AC volts• 2- and 4-wire Resistance• Frequ

Pagina 13 - 3499A/B/C Commands (cont’d.)

Agilent Technologies’ Test and MeasurementSupport, Services, and AssistanceAgilent Technologies aims to maximize the valueyou receive, while minimizin

Pagina 14

3ModulesThe 34980A implements asuperior selection of switchtopologies. The 34980A switchtopologies are similar to3499A/B/C switch modules andinclude m

Pagina 15

4Module Type 34980A 3499A/B/CMultiplexer 34921A 40 Ch armature 300V 1A N2260A 40 Ch armature 200V 1A34922A 70 Ch armature 300V 1A N2266A 40 Ch reed

Pagina 16

5User InterfaceThe 34980A offers the mostmodern instrument I/O options forinterfacing a controller PC with theswitch system: GPIB, USB andLAN. All th

Pagina 17

6Web Page InterfaceThe 34980A comes with a built-indetailed instrument web page thatallows you to remotely connect andcommunicate with the mainframean

Pagina 18

7Table 4. Command comparisons34980A 3499A/B/CClose channel 10 on the module in slot 3ROUTe:CLOS (@3010) [ROUTe:]CLOS (@310)Scan channels 0 through 40

Pagina 19

8Scan FeatureThe scan feature is a sequence ofalternating switch closures andmeasurements. This feature isprovided by both the 34980A anda 3499A/B/C c

Pagina 20

9Monitor FeatureThe 34980A monitor featureallows you to monitor readingsacquired by the switch/measuresystem. You can also monitorreadings acquired wi