Agilent Technologies 281A/B Manuale Utente

Navigare online o scaricare Manuale Utente per Misurazione, test & controllo Agilent Technologies 281A/B. Agilent 11974 Series Preselected Millimeter Mixers Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 8
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Agilent 11974 Series
Preselected Millimeter Mixers
RF Sections Available in Four Bands
from 26.5 to 75 GHz
Data Sheet
For the first time, preselected
signal analysis is available to
75 GHz. With preselection, you can
quickly and easily characterize all
signals of interest. No images or
multiples are displayed to confuse
the measurement. Time consuming
signal-identification routines are
eliminated.
Figure 1 shows how true signals can
be obscured by displayed multiples
and images in an unpreselected
system. Figure 2 shows how only the
true signals are displayed when an
Agilent Technologies 11974 Series
preselected millimeter mixer is used
in making the measurement.
Whether your millimeter-frequency
application is component or system
testing, signal surveillance or EMI
measurements, your software
development and verification time will
be reduced and your measurement
times will be decreased. Simply place
a marker on a signal—all responses
are real—and perform a preselector
peak. The analyzer then displays
the amplitude and frequency of the
signal. No time is lost creating and
running signal identification routines,
which used to be required to separate
true responses from multiples and
images.
Each 11974 Series preselected
millimeter mixer is characterized for
conversion loss versus frequency.
Calibration accuracy ranges from
1 dB at 26.5 GHz to 2 dB at 75 GHz.
Just enter the conversion loss data
into your host spectrum analyzer
and then make amplitude-calibrated
measurements.
Choose your host spectrum analyzer
Agilent 11974 Series preselected
millimeter mixers are compatible with
Agilent’s 8566B, 8560 Series and
E4407B of rugged portables
1
, 70000
Series modular spectrum analyzers
and the E4440A/46A/48A PSA
Series
1
.
Requires Option AYZ (external mixing).1.
Figure 1. Figure 2.
Vedere la pagina 0
1 2 3 4 5 6 7 8

Sommario

Pagina 1 - Agilent 11974 Series

Agilent 11974 SeriesPreselected Millimeter Mixers RF Sections Available in Four Bandsfrom 26.5 to 75 GHzData SheetFor the first time, preselected sign

Pagina 2 - System confi guration

2Added Benefi ts of Preselected Millimeter MeasurementsReduced overload from many signalsPreselected millimeter mixers reduce susceptibility to overloa

Pagina 3 - Specifi cations

3Specifi cationsUnless noted, all specifications describe warranted performance under the following conditions: 5-minute warm-up from ambient condition

Pagina 4

4Specifi cationsAmplitudeThird-order intercept (nominal)(For two signals spaced less than 200 MHz apart)11974A ≥ +13 dBm11974Q ≥ +13 dBm11974U ≥ +13 dB

Pagina 5

5Specifi cationsGeneral specificationsEnvironmental specifi cations type tested to MIL-T-28800C, Class 5 environmental conditions as listed below:Temper

Pagina 6 - Compatibility Information

6Compatibility InformationThe following table lists compatibility requirements of host spectrum analyzers. Installation by a service center or personn

Pagina 7 - Ordering Information

7Ordering Information 11974A 26.5 to 40 GHz11974Q 33 to 50 GHz11974U 40 to 60 GHz11974V 50 to 75 GHzOption 11974X-001: Input isolator attached and inc

Pagina 8 - Revised: October 6, 2008

Remove all doubtOur repair and calibration services will get your equipment back to you, performing like new, when prom-ised. You will get full value

Commenti su questo manuale

Nessun commento