Agilent Technologies 281A/B Manuale Utente Pagina 6

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 8
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 5
6
Compatibility Information
The following table lists compatibility requirements of host spectrum analyzers. Installation by a service center or
personnel qualified by Agilent is required for the E4440A, E4446A, E4448A, and E4407B Option AYZ upgrade kits.
70000 modular measurement system with 70907 external mixer interface module
Model S/N prefi x Compatibility kit
70907A all 70907A-K74 upgrade kit required
1
70907B all Fully compatible provided 70900A/B LO meets the following requirements:
Firmware date code YYMMDD LO upgrade kit required
850730 70907B-098
860203 (Firmware + CPU)
861015 70907B-099
870501 (Firmware only)
880314
880901
890606 Fully compatible
Rugged portable spectrum analyzers
Model S/N prefi x Compatibility kit
8560A < 3003A 8560A-K74 upgrade kit required
2
8560A ≥ 3003A Fully compatible
2
8561A all 8561A-K74 upgrade kit required
3
8561B < 3003A 8561 B-K74 upgrade kit required
8561B ≥ 3003A Fully compatible
8562A/B all 8562A-K74 upgrade kit required
3
8560E/EC all Fully compatible
8561E/EC all Fully compatible
8562E/EC all Fully compatible
8563A/E/EC all Fully compatible
E4407B
5
all Fully compatible
PSA Series with Option AYZ
Model S/N prefi x Compatibility kit
E4440A/46A/48A all Fully compatible
8566A/B with 11975A LO amplifier
Model S/N prefi x Compatibility kit
8566A < 2007A
4
No upgrade kit available
8566A ≥ 2007A
4
8566AB conversion kit previously installed:
Firmware datecode < 89.10.10: 8566B-K74 upgrade kit required
Firmware datecode ≥ 89.10.10: 8566B-K75 upgrade kit required
8566AB conversion kit NOT previously installed:
(two kits required) 8566AB conversion kit, 8566B-K75 upgrade kit
8566B < 2948
4
8566B-K74 upgrade kit required
8566B ≥ 2948
4
Fully compatible
Mixer bias capability is converted to preselector peak, resulting in activation of a preselector peaking with the BIAS PEAK function. Sweep times must be manually
controlled in wide spans to avoid oversweeping the preselector.
External mixing is not available with the 8560EC if a built-in tracking generator, Option 8560EC-002, has been installed.
Operation with 11974 Series will require entry of a frequency offset. Preselector peaking is performed manually with a screwdriver adjustment. Sweep times must be
manually controlled in wide spans to avoid oversweeping the preselector.
The serial number prefi x on the 8566A/B refers to the RF section.