Agilent Technologies N9344C Manuale Utente Pagina 13

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 17
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 12
13
Description Option Additional information
Swept-tuned and FFT Standard Allows selection of swept-tuned or FFT to be made manually or defer to the
mode determined by the HSA. Note: FFT mode can be turned on when RBW is
set to 30 kHz or lower
Autotune Standard Automatically find, tune, and zoom in on the signal
Trace math Standard Provides true power calculations with results displayed in dBm
Simultaneous
detectors
Standard Features a total of four traces and support simultaneous detectors. Four
different detectors can be used on four different traces in a single sweep
Peak table Standard Displays a list of up to 10 signal peaks from the selected trace. Exporting the
peak table to .csv file is supported
AM/FM tuner Standard Supplies AM/FM demodulated audio that can be heard with the internal speaker
or the provided earphone. Speaker volume and demodulation delay time can be
adjusted to meet your specific needs
Marker zoom-in/out Standard Moves the marker to the signal of interest, zooms in to see more details with
one button push, and zooms out to see the whole frequency band
Noise marker Standard Measures noise level in dBm/Hz or dBuV/Hz
Marker logging Standard Records the marker readout over time to a .CSV file. Location information can be
tagged if GPS is turned on
Band power Standard Measures both power and power spectral density in a specified channel
bandwidth
Channel power Standard Computes and displays the power between the reference marker and the
associated delta marker. Results can be displayed in a bar chart, or a meter
graphical user interface (GUI)
Adjacent channel
power ratio (ACPR)
Standard Finds the transmitter’s potential for interfering with a receiver on an adjacent
(upper or lower) channel. Up to 6 pairs of adjacent channels can be set up
Occupied bandwidth
(OBW)
Standard Determines the band of frequencies that contain a specified percentage of the
total power within the measurement span
Channel table Standard Includes the major wireless communication standards and can be customized
Mapping Standard Captures data with marker logging, or the optional channel scanner, and exports
data files (.CSV and .KML) to use with mapping applications like Google Earth
and MapInfo
High accuracy power
measurement
Option PWM Makes true average power measurements with Agilent U2000 Series USB power
sensors
Task planner Option TPN Reduces test setup time by 95%, delivers test automation and consistency, and
makes it easy to capture test results, generate reports, and share task plans
with others
Measurement capabilities