4
5
Models and specifi cations
Included BenchLink Data Logger
software makes it easy to capture data
for further analysis.
Agilent 34830A BenchLink Data
Logger Pro allows for advanced data
logging and decision making without
programming
Model Description
34970A 3-slot mainframe with internal 6½ digit DMM. GPIB, RS-232 and 50 K reading non-volatile memory with
timestamp
34970A Description Scan Max Max Comments
Plug-in Modules ch/sec Voltage Current
34901A 20 ch. multiplexer 60 300 V 1 A 2 current channels (22 ch.
(2/4-wire) total); built-in cold junction
reference; connects to
internal DMM
34902A 16 ch. multiplexer 250 300 V 50 mA Built-in cold junction
(2/4 wire) reference; reed relays multi-
plex inputs to internal DMM
34903A 20-ch. actuator/GP switch 120 300 V 1 A Form C (SPDT) switches; no
connection to internal DMM
34904A 4x8 matrix 120 300 V 1 A 2-wire, full crosspoint; no
connection to internal DMM
34905A 2 GHz dual 1:4 60 42 V 0.7 A 1 GHz through provided
RF mux 50Ω BNC-to-SMB adapter
cables; no connection to
internal DMM
34906A 2 GHz dual 1:4 60 42 V 0.7 A 1 GHz through provided
RF mux 75Ω BNC-to-SMB adapter
cables; no connection to
internal DMM
34907A 2, 8-bit digital I/O ports NA 42 V 400 mA Open drain
26-bit, 100 kHz event counter 42 Gated, selectable input threshold;
2,16-bit analogue outputs ±12 V 10 mA Earth referenced; calibrated;
no connection to internal DMM
34908A 40-ch. single-ended mux 60 300 V 1 A Common low, no 4-wire meas.
Built-in cold junction reference;
connects to internal DMM
Options and Accessories
• Option 001 Delete Internal DMM
• Option 1CM Rack mount kit
• 34307A 10-pack of J-type thermocouples
• 34308A 5-pack of 10 kΩ thermistors
• Three-slot mainframe, choice of 8 plug-in modules
• Up to 60 2-wire mux or 96 2-wire matrix cross-points in
one mainframe
• Built-in DMM with 6½ digits (22 bits) of resolution
• Scan rates of up to 250 channels/second
• Measures and converts 11 different input signals:
temperature with thermocouples, RTDs, and thermistors;
DC/AC volts; 2- and 4-wire resistance; frequency and
period; DC/AC current
• Includes BenchLink Data Logger software to confi gure and
control tests, display results and move data for
further analysis
Dedicated data-acquisition performance at PC plug-in prices
34970A Data Acquisition/Switch System
⎮ www.agilent.com/fi nd/34970A www.agilent.com/fi nd/34970A ⎮
Scan List A
(Base)
Scan List C
Scan List B
Start
Event
Events
Event
Event
Events
Events
8dcigda>chigjbZcih
HZcYCdi^[^XVi^dch
HideHXVc
8dcigda>chigjbZcih
HZcYCdi^[^XVi^dch
HideHXVc
8dcigda>chigjbZcih
HZcYCdi^[^XVi^dch
HideHXVc
Commenti su questo manuale