Agilent Technologies N5230C Manuale Utente

Navigare online o scaricare Manuale Utente per Misurazione, test & controllo Agilent Technologies N5230C. 2-Port PNA-L [it] Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 118
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Technical Specifications
Agilent Technologies
PNA Series Network Analyzers
N5230A/C
Options 020/025, 120/125, 220/225, 420/425, and
520/525
(2-Port PNA-L)
Manufacturing Part Number: N5230-90016
Printed in USA
Print Date: November 9, 2010
Supersedes: August 26, 2009
© Agilent Technologies, Inc. 2004 - 2010 All rights reserved.
Vedere la pagina 0
1 2 3 4 5 6 ... 117 118

Sommario

Pagina 1 - Technical Specifications

Technical SpecificationsAgilent TechnologiesPNA Series Network AnalyzersN5230A/COptions 020/025, 120/125, 220/225, 420/425, and 520/525 (2-Port PNA-L)

Pagina 2 - Documentation Warranty

6 Table 2. Extended Dynamic Range1 Description Specification (dB) at Direct Receiver Access Input Typical (dB) at Direct Receiver Access Input Opti

Pagina 4

97 Dynamic Accuracy, 40 - 50 GHz, Option 520 or 525

Pagina 5 - N5230-90016, Rev. 2010-11-09

98 a Dynamic accuracy is verified with the following measurements: • compression over frequency • IF linearity at a single frequency of 1.195 G

Pagina 6

99Table 19. Test Port Input (Group Delay)a Description Specification Supplemental Information (typ.) Aperture (selectable) (frequency span)/(numb

Pagina 7 - Definitions

100General Information Table 20. Miscellaneous Information Description Specification Supplemental Information System IF Bandwidth Range Option 020

Pagina 8 - Table 1. System Dynamic Range

101Table 22. Rear Panel Information Description Supplemental Information Trigger Inputs/Outputs BNC(f), TTL/CMOS compatible 10 MHz Reference In Con

Pagina 9

102 Table 22. Rear Panel Information (Continued) Description Supplemental Information LAN 10/100BaseT Ethernet, 8-pin configuration; auto selects

Pagina 10

103Measurement Throughput Summary Table 24. Typical Cycle Timea (ms) for Measurement Completion Description Typical Number of Points 201 401 80

Pagina 11

104Table 25. (Options 020/025, 120/125, only) Cycle Time vs IF Bandwidth Applies to the Preset condition (201 points, correction off) except for the

Pagina 12

105 Table 26. (Options 220/225, 420/425, 520/525 only) Cycle Time vs IF Bandwidth Applies to the Preset condition (201 points, correction off) excep

Pagina 13

7N5230A/C Corrected System Performance with 3.5mm Connectors Options 220/225, 420/425, 520/525: From 10 MHz to 45 MHz, performance is characterized a

Pagina 14

106Table 27. (Options 020/025, 120/125, only) Cycle Time vs Number of Points Applies to the Preset condition (correction off) except for the followin

Pagina 15

107Table 28. (Options 220/225, 420/425, 520/525 only) Cycle Time vs Number of Points Applies to the Preset condition (correction off) except for the

Pagina 16

108Table 29. Data Transfer Time (ms) Description Typical Number of Points 201 401 1601 16,001 SCPI over GPIB (program executed on external PC)

Pagina 17

109Specifications: Front-Panel Jumpers ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ Model N5230A/C Options 025, 125, 225, 425, and 525 ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯

Pagina 18

110Table 32: Reference Outputs (Reference 1 Source Out, Reference 2 Source Out) @ Max Specified Output Power Description Specification Typical

Pagina 19

111Table 34: Coupler Inputs (Port 1 Cplr Thru, Port 2 Cplr Thru) Insertion Loss of Coupler Thru Description Specification Typical Option 025,

Pagina 20

112Table 35: Coupler Outputs (Port 1 Cplr Arm, Port 2 Cplr Arm) Description Specification Typical Option 025, 125 Option 225 Option 425, 525

Pagina 21

113Test Set Block Diagrams N5230A/C Option020, or 120, or 220, or 420, or 520 (Standard Test Set and Standard Power Range)

Pagina 22

114N5230A/C Option025, or 125, or 225, or 425, or 525 (Configurable Test Set and Extended Power Range) Item Description Item Description

Pagina 23

8 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Pagina 24

9 Reflection Uncertainty (Specifications)

Pagina 25

10 Table 4. 85052B Calibration Kit N5230A/C- Option 025/125 (Configurable Test Set and Extended Power Range) Applies to the N5230A/C Option 025/125

Pagina 26

11 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Pagina 27

12 Reflection Uncertainty (Specifications)

Pagina 28

13 Table 5. 85052B Calibration Kit N5230A/C- Option 220 (Standard Test Set and Standard Power Range) Applies to the, N5230A/C Option 220 analyzers,

Pagina 29 - Description

14 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Pagina 30

15 Reflection Uncertainty (Specifications)

Pagina 31

Documentation WarrantyTHE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED "AS IS," AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTU

Pagina 32

16 Table 6. 85052B Calibration Kit N5230A/C- Option 225 (Configurable Test Set and Extended Power Range) Applies to the, N5230A/C Option225 analyze

Pagina 33

17NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Pagina 34

18 Reflection Uncertainty (Specifications)

Pagina 35

19⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ N4691B Electronic Calibration (ECal) Module ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ Table 7. N469

Pagina 36

20 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Pagina 37

21 Reflection Uncertainty (Specifications)

Pagina 38

22 Table 8. N4691B Electronic Calibration Module N5230A/C- Option 225 (Configurable Test Set and Extended Power Range) Applies to the, N5230A/C Opti

Pagina 39

23 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Pagina 40

24 Reflection Uncertainty (Specifications)

Pagina 41 - 85032B Calibration Kit

25 N5230A/C Corrected System Performance with 2.4mm Connectors ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ 85056A Calibration Kit: ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯

Pagina 42

Contacting AgilentAssistance with test and measurement needs and information on finding a local Agilent office are available on the Web at:http://www.

Pagina 43

26 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Pagina 44

27 Reflection Uncertainty (Specifications)

Pagina 45

28 Table 10. 85056A Calibration Kit N5230A/C- Option 425 or 525 (Configurable Test Set and Extended Power Range) Applies to the N5230A/C Option425 o

Pagina 46

29NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Pagina 47

30 Reflection Uncertainty (Specifications)

Pagina 48

31 ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ N4693A Electronic Calibration Module ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ Table 11. N4693A El

Pagina 49

32 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Pagina 50 - Table 16. Test Port Output

33 Reflection Uncertainty (Specifications)

Pagina 51 - (Continued)

34 Table 12. N4693A Electronic Calibration Module N5230A/C- Option 425 or 525 (Configurable Test Set and Extended Power Range) Applies to the N5230A

Pagina 52

35NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Pagina 53

This page intentionally left blank.

Pagina 54

36 Reflection Uncertainty (Specifications)

Pagina 55

37N5230A/CCorrected System Performance with Type-N Connectors ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ 85032B Calibration Kit ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯

Pagina 56

38 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Pagina 57 - Table 17. Test Port Input

39 Reflection Uncertainty (Specifications)

Pagina 58

40 Table 14. 85032B Calibration Kit N5230A/C- Option 025 (Configurable Test Set and Extended Power Range) Applies to the, N5230A/C Option 025 analyz

Pagina 59

41NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Pagina 60

42 NOTE: The following graphs also apply to the “C” model of the analyzer. Reflection Uncertainty (Specifications)

Pagina 61

43 Table 15. Uncorrected System Performance Description Specifications Typical Options 020, 025, 120, 125 Options 220, 225 Options420, 520Options

Pagina 62

44 Table 15. Uncorrected System Performance (Continued) Options 020, 025, 120, 125 Options 220, 225 Options420, 425 Options520, 525Options020, 02

Pagina 63

45 Table 15. Uncorrected System Performance (Continued) Description Specifications Typical Options 020, 025, 120, 125 Options 220, 225 Opti

Pagina 64

1Technical Specifications for the N5230A/C N5230-90016, Rev. 2010-11-09 Options 020/025, 120/125, 220/225, 420/425, or 520/525 (2-Port PNA-L) Defini

Pagina 65

46 Table 16. Test Port Output1 Specifications Typicals Options 020, 025 Options 120, 125 Options 220, 225 Options 420, 425 Options 520, 525

Pagina 66

47 Table 16. Test Port Output1 (Continued) Specifications Typical Options 020, 025, 120, 125 Options 220, 225 Options 420, 425 O

Pagina 67

48 Table 16. Test Port Output1 (Continued) Specifications Typical Options 020, 120 Options 025, 125 Options 220, 225 Option 420 Optio

Pagina 68 - Options 020, 025, 120, 125

49 Table 16. Test Port Output1 (Continued) Specifications Typical Options 020, 120 Options 025, 125 Options 220, 225 Option 420 Option

Pagina 69

50 Table 16. Test Port Output1 (Continued) Specifications Typical Option 020, 120 Option 025, 125 Option 220 Option 225 Option 420, 520

Pagina 70

51 Table 16. Test Port Output1 (Continued) Description Specifications Typical -- Options 020, 025, 120, 125 Options 220, 225, 420, 425, 520,

Pagina 71

52 Table 16. Test Port Output1 (Continued) Description Specifications Typicals -- Options 020, 025, 120, 125, 220, 225, 420, 520, 425, 525 No

Pagina 72

53 Table 17. Test Port Input Description Specification Typical Options 020, 025, 120, 125 Options 220, 225 Options 420, 425 Options 520, 5

Pagina 73

54 Table 17. Test Port Input (Continued) Description Specification Typical Options 020, 025, 120, 125 Options 220, 225 Options 420, 425 Op

Pagina 74

55 Table 17. Test Port Input (Continued) Description Specification Typical Options 025, 125 Options 225 Options 425 Options 525 Option

Pagina 75 - Options 220, 225

2 Table 22. Rear Panel Information...101 Table 23. Analyzer Dimensi

Pagina 76

56 Table 17. Test Port Input (Continued) Description Specification Typical Options 025, 125 Options 225 Options 425 Options 525 Optio

Pagina 77

57 Table 17. Test Port Input (Continued) Description Specification Typical Options 220, 225 Options 420, 520 Options 425, 525 Options 220,

Pagina 78

58 Table 17. Test Port Input (Continued) Description Specification Typical Options 020, 120, 025, 125 Test Port Compression - 0.1 dB Pow

Pagina 79

59 Table 17. Test Port Input (Continued) Trace Noise Magnitude6 1 kHz IF bandwidth, ratioed measurement, nominal power at test port. 300 kHz to 10

Pagina 80

60 Table 17. Test Port Input (Continued) Specification Typical Options 020, 120, 025, 125 Options 020, 120, 025, 125 Trace Noise Magnitude6 (c

Pagina 81

61 Table 17. Test Port Input (Continued) Description Specification Technical Options 020, 120, 025, 125 Options 020, 120, 025, 125 Trace Noise

Pagina 82

62 Table 17. Test Port Input (Continued) Description Specification Typical -- -- -- -- Option 020, 025, 120, 125 Option 220, 225 Options 4

Pagina 83

63 Table 17. Test Port Input (Continued) Description Specifications Typical Options 020, 120 Option 220 Options 420, 520 Options 025, 125

Pagina 84

64 Table 18. Dynamic Accuracy (Specificationa) Accuracy of the test port input power reading relative to the reference input power level. NOTE: The

Pagina 85 - Options 420, 425, 520, 525

65 Dynamic Accuracy, 1 MHz- 10 MHz, Option 020, 025, 120, or 125

Pagina 86

3Definitions All specifications and characteristics apply over a 25 °C ±5 °C range (unless otherwise stated) and 90 minutes after the instrument has

Pagina 87

66 Dynamic Accuracy, 10 MHz- 1 GHz, Option 020, 025, 120, or 125

Pagina 88

67 Dynamic Accuracy, 1 - 8 GHz, Option 020, 025, 120, or 125

Pagina 89

68 Dynamic Accuracy, 8 - 10.5 GHz, Option 120 or 125

Pagina 90

69 Dynamic Accuracy, 10.5 - 12.5 GHz, Option 120 or 125

Pagina 91

70 Dynamic Accuracy, 12.5 - 13.5 GHz, Option 120 or 125

Pagina 92

71 Options 220, 225 Dynamic Accuracy, 0.045 GHz, Option 220 or 225

Pagina 94

73 Dynamic Accuracy, 0.500 GHz, Option 220 or 225

Pagina 96

75 Dynamic Accuracy, 0.500 - 2 GHz, Option 220 or 225

Pagina 97

4 Corrected System Performance The specifications in this section apply for measurements made with the N5230A/C analyzer with the following condition

Pagina 99

77 Dynamic Accuracy, 2 - 12.5 GHz, Option 220 or 225

Pagina 101

79 Dynamic Accuracy, 12.5 - 20 GHz, Option 220 or 225

Pagina 103

81Options 420, 425, 520, 525 Dynamic Accuracy, 0.045 GHz, Option 420, 425, 520, or 525

Pagina 105

83 Dynamic Accuracy, 0.500 GHz, Option 420, 425, 520, or 525

Pagina 107 - Table 24. Typical Cycle Time

85 Dynamic Accuracy, 0.500 - 2 GHz, Option 420, 425, 520, or 525

Pagina 108

5 Table 1. System Dynamic Range1 (Continued) Description Specification (dB) at Test Port Typical (dB) at Test Port Options 025, 125 Option 22

Pagina 110 - Span = 100 MHz

87 Dynamic Accuracy, 2 - 8 GHz, Option 420, 425, 520, or 525

Pagina 112

89 Dynamic Accuracy, 8 - 12.5 GHz, Option 420, 425, 520, or 525

Pagina 114 - Output Power

91 Dynamic Accuracy, 12.5 - 20 GHz, Option 420, 425, 520, or 525

Pagina 116

93 Dynamic Accuracy, 20 - 31.25 GHz, Option 420, 425, 520, or 525

Pagina 118

95 Dynamic Accuracy, 31.25 - 40 GHz, Option 420, 425, 520, or 525

Commenti su questo manuale

Nessun commento