Agilent Technologies N5230C Guida Utente

Navigare online o scaricare Guida Utente per Misurazione, test & controllo Agilent Technologies N5230C. Agilent Technologies N5230C User`s guide Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 54
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Agilent Technologies
U3025AE10
User’s Guide
Use this manual with the following document:
PNA Series Network Analyzer On-line Help System
Manufacturing Part Number: U3025-90001
Printed Date: April 7, 2011
Supersede: March 2009
© Copyright 2007-2009, 2011 Agilent Technologies, Inc. All rights reserved.
Vedere la pagina 0
1 2 3 4 5 6 ... 53 54

Sommario

Pagina 1 - U3025AE10

Agilent Technologies U3025AE10User’s GuideUse this manual with the following document:PNA Series Network Analyzer On-line Help System Manufacturing Pa

Pagina 2 - Warranty Statement

4 User’s Guide U3025-90001U3025AE10 DescriptionNetwork Analyzer Requirement • All PNA, PNA-L Network Analyzers require Option 551, which adds N-Port e

Pagina 3 - Definitions

User’s Guide U3025-90001 5 U3025AE10 Available OptionsAvailable OptionsTest Set OptionsThe U3025AE10 has two available Test Set options: Refer to “Sys

Pagina 4

6 User’s Guide U3025-90001U3025AE10 General SpecificationsGeneral SpecificationsSpecifications for the Test Set are characteristic for the system perf

Pagina 5 - Contents

User’s Guide U3025-90001 7 U3025AE10 General SpecificationsEnvironmental Requirements Refer to the PNA-L or PNA-X standard documentation for environme

Pagina 6

8 User’s Guide U3025-90001U3025AE10 General SpecificationsFrequency Range and Maximum Power LevelsThe U3025AE10 frequency range is 10 MHz to 50 GHz.CA

Pagina 7

User’s Guide U3025-90001 9 U3025AE10 General SpecificationsTypical Reflection Tracking Specifications for the Test Set are typical. System performance

Pagina 8

10 User’s Guide U3025-90001U3025AE10 Front and Rear Panel FeaturesFront and Rear Panel FeaturesFigure 3 Front Panel (Multiport Test Set) Access Ports

Pagina 9 - Description

User’s Guide U3025-90001 11 U3025AE10 Front and Rear Panel FeaturesStandby SwitchNote that this switch is Standby only, not a line switch. The main po

Pagina 10 - Verifying the Shipment

12 User’s Guide U3025-90001U3025AE10 Front and Rear Panel FeaturesLine ModuleThe line fuse, as well as a spare, reside within the line module. Figure

Pagina 11 - Available Options

User’s Guide U3025-90001 13 U3025AE10 System Setup E8363C, E8364C or N5230CSystem Setup E8363C, E8364C or N5230C WARNING The opening of covers or remo

Pagina 12 - General Specifications

ii User’s Guide Warranty StatementTHE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED “AS IS,” AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FU

Pagina 13 - Environmental Requirements

14 User’s Guide U3025-90001U3025AE10 System Setup E8363C, E8364C or N5230C4. Place the network analyzer on top of the Test Set and ensure that the fro

Pagina 14 - 0.01w 0.98w+ 0.99w=

User’s Guide U3025-90001 15 U3025AE10 System Setup E8363C, E8364C or N5230CRF Interface Cable Connections Figure 10 illustrates the setup configuratio

Pagina 15 - (± 2 dB 40 to 50 GHz)

16 User’s Guide U3025-90001U3025AE10 System Setup E8363C, E8364C or N5230C3. Connect the PNA Test Set I/O cable (8120-6818) to the U3025AE10 Test Set

Pagina 16 - Front and Rear Panel Features

User’s Guide U3025-90001 17 U3025AE10 Controlling the System with E8363/4C and N5230CControlling the System with E8363/4C and N5230CThis section will

Pagina 17 - Bias Tee Input (Option 002)

18 User’s Guide U3025-90001U3025AE10 Controlling the System with E8363/4C and N5230CPNA Multiport Mode for E8363/4C and N5230C with Option 551The PNA

Pagina 18 - 12 User’s Guide U3025-90001

User’s Guide U3025-90001 19 U3025AE10 Controlling the System with E8363/4C and N5230CExternal Test Set Control FeatureTo verify that the network appli

Pagina 19 - Screws (0515-1619)

20 User’s Guide U3025-90001U3025AE10 Controlling the System with E8363/4C and N5230CSelect the Port Control down arrow for Ports 9 through 12. Figure

Pagina 20 - 14 User’s Guide U3025-90001

User’s Guide U3025-90001 21 U3025AE10 Controlling the System with E8363/4C and N5230CNew Trace Measure S-ParameterS-Parameter Tab: Multiple S-Paramet

Pagina 21 - 45 (x4)

22 User’s Guide U3025-90001U3025AE10 Controlling the System with E8363/4C and N5230CFigure 21 12-Port New Trace Measure (S88 - S12_12)Balanced Tab: B

Pagina 22 - 16 User’s Guide U3025-90001

User’s Guide U3025-90001 23 U3025AE10 Controlling the System with E8363/4C and N5230CReceivers Tab: The S-Parameter measurements can be ratioed with

Pagina 23 - User’s Guide U3025-90001 17

User’s Guide iiiSafety Notes The following safety notes are used throughout this document. Familiarize yourself with each of these notes and its mean

Pagina 24 - 18 User’s Guide U3025-90001

24 User’s Guide U3025-90001U3025AE10 Controlling the System with E8363/4C and N5230CSweep Setup for Multiport and Standalone PNA Modes When the Test S

Pagina 25 - Control Lines

User’s Guide U3025-90001 25 U3025AE10 Controlling the System with E8363/4C and N5230CN-Port Calibration with E8363/4C and N5230C It is recommended tha

Pagina 26 - 20 User’s Guide U3025-90001

26 User’s Guide U3025-90001U3025AE10 Controlling the System with E8363/4C and N5230C1. On the network analyzer select Response > Cal Wizard. a. If

Pagina 27 - New Trace Measure S-Parameter

User’s Guide U3025-90001 27 U3025AE10 DUT Control LinesDUT Control LinesThe 15 pin female D-Sub connector on the rear panel provides 8 latched data co

Pagina 28 - Scroll Bar

28 User’s Guide U3025-90001U3025AE10 DUT Control LinesNOTE All DUT control lines must be set with each command sent. Logic 0 = high Figure 27 DUT Cont

Pagina 29 - Figure 23 Receiver Ports

User’s Guide U3025-90001 29 U3025AE10 DUT Control LinesSetting the Variable Source VoltageThe output voltage of pin 12 can be varied from +2 to +5 V.

Pagina 30 - 24 User’s Guide U3025-90001

30 User’s Guide U3025-90001U3025AE10 DUT Control LinesUsing an External Power SupplyFigure 29 illustrates an example of the connection between the DUT

Pagina 31 - User’s Guide U3025-90001 25

User’s Guide U3025-90001 31 U3025AE10 DUT Control LinesFigure 30 Block Diagram of DUT ControlTable 8 DUT Control Specifications Item SpecificationsCon

Pagina 32 - 26 User’s Guide U3025-90001

32 User’s Guide U3025-90001U3025AE10 Operational Check ProceduresOperational Check ProceduresThis section provides the test calibration procedure to c

Pagina 33 - DUT Control Lines

User’s Guide U3025-90001 33 U3025AE10 Operational Check ProceduresEquipment RequiredThe Agilent U3025AE10 requires that the user be familiar with the

Pagina 34

iv User’s Guide

Pagina 35 - U3025AE10 DUT Control Lines

34 User’s Guide U3025-90001U3025AE10 Operational Check Procedures1-Port Calibration Procedure1. Connect the ECal or the mechanical cal kit to Port 1 o

Pagina 36 - U3025AE10 DUT Control Lines

User’s Guide U3025-90001 35 U3025AE10 Operational Check Procedures6. Repeat step 1 thru step 5 (1-Port Calibration Procedure) for Ports 2 thru 12. Whe

Pagina 37

36 User’s Guide U3025-90001U3025AE10 Operational Check Procedures9. From the Cal Sets drop-down menu, select 999.1 and check Enable. Select the Reflec

Pagina 38 - Operational Check Procedures

User’s Guide U3025-90001 37 U3025AE10 Operational Check Procedures10.Compare the Reflection Tracking (1,1) trace to the appropriate limits in Table 9

Pagina 39 - Equipment Required

38 User’s Guide U3025-90001U3025AE10 Troubleshooting Operational Check FailuresTroubleshooting Operational Check Failures If your test results fail th

Pagina 40 - 34 User’s Guide U3025-90001

User’s Guide U3025-90001 39 U3025AE10 Theory of OperationTheory of Operation The following is a description of the operation of the U3025AE10. Referen

Pagina 41 - User’s Guide U3025-90001 35

40 User’s Guide U3025-90001U3025AE10 Theory of OperationSystem Block DiagramsFigure 37 Standard ConfigurationU3025AE10Standard ConfigurationMechanical

Pagina 42 - 36 User’s Guide U3025-90001

User’s Guide U3025-90001 41 U3025AE10 Service InformationService Information Refer to “Contacting Agilent” on page 48.WARNING No operator serviceable

Pagina 43 - User’s Guide U3025-90001 37

42 User’s Guide U3025-90001U3025AE10 Safety and Regulatory InformationSafety and Regulatory Information IntroductionReview this product and related do

Pagina 44 - 38 User’s Guide U3025-90001

User’s Guide U3025-90001 43 U3025AE10 Safety and Regulatory InformationBefore Applying PowerVerify that the premises electrical supply is within the r

Pagina 45 - Theory of Operation

ContentsContents-1U3025AE10Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 46 - System Block Diagrams

44 User’s Guide U3025-90001U3025AE10 Safety and Regulatory InformationServicingWARNING Danger of explosion if battery is incorrectly replaced. Replace

Pagina 47 - Service Information

User’s Guide U3025-90001 45 U3025AE10 Electrostatic Discharge ProtectionElectrostatic Discharge ProtectionProtection against electrostatic discharge (

Pagina 48 - Statement of Compliance

46 User’s Guide U3025-90001U3025AE10 Regulatory InformationRegulatory Information Instrument MarkingsThis section contains information that is require

Pagina 49 - Before Applying Power

User’s Guide U3025-90001 47 U3025AE10 Regulatory InformationBattery CollectionDo not throw batteries away but collect as small chemical waste, or in a

Pagina 50 - Servicing

48 User’s Guide U3025-90001U3025AE10 Agilent Support, Services, and AssistanceAgilent Support, Services, and AssistanceService and Support OptionsThe

Pagina 51 - User’s Guide U3025-90001 45

Contents-2ContentsService Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 52 - ICES/NMB-001

User’s Guide U3025-90001 1U3025AE10

Pagina 53

2 User’s Guide U3025-90001U3025AE10 IntroductionIntroductionThis document describes how to use the U3025AE10 Multiport Test Set with the Agilent E8363

Pagina 54 - Contacting Agilent

User’s Guide U3025-90001 3 U3025AE10 DescriptionDescription The Agilent U3025AE10 is a 10-Port mechanical switching extension Test Set (10 MHz to 50 G

Commenti su questo manuale

Nessun commento