Agilent Technologies U3025AE10User’s GuideUse this manual with the following document:PNA Series Network Analyzer On-line Help System Manufacturing Pa
4 User’s Guide U3025-90001U3025AE10 DescriptionNetwork Analyzer Requirement • All PNA, PNA-L Network Analyzers require Option 551, which adds N-Port e
User’s Guide U3025-90001 5 U3025AE10 Available OptionsAvailable OptionsTest Set OptionsThe U3025AE10 has two available Test Set options: Refer to “Sys
6 User’s Guide U3025-90001U3025AE10 General SpecificationsGeneral SpecificationsSpecifications for the Test Set are characteristic for the system perf
User’s Guide U3025-90001 7 U3025AE10 General SpecificationsEnvironmental Requirements Refer to the PNA-L or PNA-X standard documentation for environme
8 User’s Guide U3025-90001U3025AE10 General SpecificationsFrequency Range and Maximum Power LevelsThe U3025AE10 frequency range is 10 MHz to 50 GHz.CA
User’s Guide U3025-90001 9 U3025AE10 General SpecificationsTypical Reflection Tracking Specifications for the Test Set are typical. System performance
10 User’s Guide U3025-90001U3025AE10 Front and Rear Panel FeaturesFront and Rear Panel FeaturesFigure 3 Front Panel (Multiport Test Set) Access Ports
User’s Guide U3025-90001 11 U3025AE10 Front and Rear Panel FeaturesStandby SwitchNote that this switch is Standby only, not a line switch. The main po
12 User’s Guide U3025-90001U3025AE10 Front and Rear Panel FeaturesLine ModuleThe line fuse, as well as a spare, reside within the line module. Figure
User’s Guide U3025-90001 13 U3025AE10 System Setup E8363C, E8364C or N5230CSystem Setup E8363C, E8364C or N5230C WARNING The opening of covers or remo
ii User’s Guide Warranty StatementTHE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED “AS IS,” AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FU
14 User’s Guide U3025-90001U3025AE10 System Setup E8363C, E8364C or N5230C4. Place the network analyzer on top of the Test Set and ensure that the fro
User’s Guide U3025-90001 15 U3025AE10 System Setup E8363C, E8364C or N5230CRF Interface Cable Connections Figure 10 illustrates the setup configuratio
16 User’s Guide U3025-90001U3025AE10 System Setup E8363C, E8364C or N5230C3. Connect the PNA Test Set I/O cable (8120-6818) to the U3025AE10 Test Set
User’s Guide U3025-90001 17 U3025AE10 Controlling the System with E8363/4C and N5230CControlling the System with E8363/4C and N5230CThis section will
18 User’s Guide U3025-90001U3025AE10 Controlling the System with E8363/4C and N5230CPNA Multiport Mode for E8363/4C and N5230C with Option 551The PNA
User’s Guide U3025-90001 19 U3025AE10 Controlling the System with E8363/4C and N5230CExternal Test Set Control FeatureTo verify that the network appli
20 User’s Guide U3025-90001U3025AE10 Controlling the System with E8363/4C and N5230CSelect the Port Control down arrow for Ports 9 through 12. Figure
User’s Guide U3025-90001 21 U3025AE10 Controlling the System with E8363/4C and N5230CNew Trace Measure S-ParameterS-Parameter Tab: Multiple S-Paramet
22 User’s Guide U3025-90001U3025AE10 Controlling the System with E8363/4C and N5230CFigure 21 12-Port New Trace Measure (S88 - S12_12)Balanced Tab: B
User’s Guide U3025-90001 23 U3025AE10 Controlling the System with E8363/4C and N5230CReceivers Tab: The S-Parameter measurements can be ratioed with
User’s Guide iiiSafety Notes The following safety notes are used throughout this document. Familiarize yourself with each of these notes and its mean
24 User’s Guide U3025-90001U3025AE10 Controlling the System with E8363/4C and N5230CSweep Setup for Multiport and Standalone PNA Modes When the Test S
User’s Guide U3025-90001 25 U3025AE10 Controlling the System with E8363/4C and N5230CN-Port Calibration with E8363/4C and N5230C It is recommended tha
26 User’s Guide U3025-90001U3025AE10 Controlling the System with E8363/4C and N5230C1. On the network analyzer select Response > Cal Wizard. a. If
User’s Guide U3025-90001 27 U3025AE10 DUT Control LinesDUT Control LinesThe 15 pin female D-Sub connector on the rear panel provides 8 latched data co
28 User’s Guide U3025-90001U3025AE10 DUT Control LinesNOTE All DUT control lines must be set with each command sent. Logic 0 = high Figure 27 DUT Cont
User’s Guide U3025-90001 29 U3025AE10 DUT Control LinesSetting the Variable Source VoltageThe output voltage of pin 12 can be varied from +2 to +5 V.
30 User’s Guide U3025-90001U3025AE10 DUT Control LinesUsing an External Power SupplyFigure 29 illustrates an example of the connection between the DUT
User’s Guide U3025-90001 31 U3025AE10 DUT Control LinesFigure 30 Block Diagram of DUT ControlTable 8 DUT Control Specifications Item SpecificationsCon
32 User’s Guide U3025-90001U3025AE10 Operational Check ProceduresOperational Check ProceduresThis section provides the test calibration procedure to c
User’s Guide U3025-90001 33 U3025AE10 Operational Check ProceduresEquipment RequiredThe Agilent U3025AE10 requires that the user be familiar with the
iv User’s Guide
34 User’s Guide U3025-90001U3025AE10 Operational Check Procedures1-Port Calibration Procedure1. Connect the ECal or the mechanical cal kit to Port 1 o
User’s Guide U3025-90001 35 U3025AE10 Operational Check Procedures6. Repeat step 1 thru step 5 (1-Port Calibration Procedure) for Ports 2 thru 12. Whe
36 User’s Guide U3025-90001U3025AE10 Operational Check Procedures9. From the Cal Sets drop-down menu, select 999.1 and check Enable. Select the Reflec
User’s Guide U3025-90001 37 U3025AE10 Operational Check Procedures10.Compare the Reflection Tracking (1,1) trace to the appropriate limits in Table 9
38 User’s Guide U3025-90001U3025AE10 Troubleshooting Operational Check FailuresTroubleshooting Operational Check Failures If your test results fail th
User’s Guide U3025-90001 39 U3025AE10 Theory of OperationTheory of Operation The following is a description of the operation of the U3025AE10. Referen
40 User’s Guide U3025-90001U3025AE10 Theory of OperationSystem Block DiagramsFigure 37 Standard ConfigurationU3025AE10Standard ConfigurationMechanical
User’s Guide U3025-90001 41 U3025AE10 Service InformationService Information Refer to “Contacting Agilent” on page 48.WARNING No operator serviceable
42 User’s Guide U3025-90001U3025AE10 Safety and Regulatory InformationSafety and Regulatory Information IntroductionReview this product and related do
User’s Guide U3025-90001 43 U3025AE10 Safety and Regulatory InformationBefore Applying PowerVerify that the premises electrical supply is within the r
ContentsContents-1U3025AE10Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
44 User’s Guide U3025-90001U3025AE10 Safety and Regulatory InformationServicingWARNING Danger of explosion if battery is incorrectly replaced. Replace
User’s Guide U3025-90001 45 U3025AE10 Electrostatic Discharge ProtectionElectrostatic Discharge ProtectionProtection against electrostatic discharge (
46 User’s Guide U3025-90001U3025AE10 Regulatory InformationRegulatory Information Instrument MarkingsThis section contains information that is require
User’s Guide U3025-90001 47 U3025AE10 Regulatory InformationBattery CollectionDo not throw batteries away but collect as small chemical waste, or in a
48 User’s Guide U3025-90001U3025AE10 Agilent Support, Services, and AssistanceAgilent Support, Services, and AssistanceService and Support OptionsThe
Contents-2ContentsService Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
User’s Guide U3025-90001 1U3025AE10
2 User’s Guide U3025-90001U3025AE10 IntroductionIntroductionThis document describes how to use the U3025AE10 Multiport Test Set with the Agilent E8363
User’s Guide U3025-90001 3 U3025AE10 DescriptionDescription The Agilent U3025AE10 is a 10-Port mechanical switching extension Test Set (10 MHz to 50 G