Agilent PXT Wireless Communications Test Set
User’s Guide
81
RLC Information
RLC Information
The Radio Link Control (RLC) information is described in the table below.
Field
Description
Downlink ‘A’ fields
Equivalent to VT(A) in 3GPP 36.322 section 5.1.3.1.1
Downlink ‘S’ fields
Equivalent to VT(S) in 3GPP 36.322 section 5.1.3.1.1
Downlink ‘POLL SN’ fields
If Status Reporting active, equivalent to POLL_SN in 5.2.2.1
Uplink ‘R’ fields
Equivalent to VR(R) in 3GPP 36.322 section 5.1.3.2.1
Uplink ‘SN’ fields
Equivalent to SN in 3GPP 36.322 section 5.1.3.2.1
Uplink ‘H’ fields
Equivalent to VR(H) in 36.322 section 5.1.3.2.3