Vedere la pagina 124
Solving Problems 7
16900 Series Logic Analysis Systems Installation Guide 125
If the logic analysis system powers itself down
16900A, 16902A, and 16902B logic analysis systems
The power LEDs on the frame help to figure out why a frame has powered
itself down. For safety purposes, when any of these LEDs are lit the frame
will not power back up until the power cord has been disconnected and
then reconnected.
The colors indicate:
Green — front power supply failure.
Yellow — side power supply failure.
Red — fan failure or ‘overtemp’.
For any of the above conditions, go to
http://www.agilent.com/find/contactus to contact your local service
representative.