Self-Tests 1xx for the A10 I/Q Multiplexer
NOTE These self-test errors apply to the A10 I/Q Multiplexer (Option 506)
and the A10 I/Q Multiplexer (Option 501, 502, 503, 504 or Option UNJ).
Figure 1-12
Table 1-17
Power
Supply
Voltage
(Vdc)
Connector
Pins on the
A23
Motherboa
rd
Minimum
Value (Vdc)
Maximum
Value (Vdc)
Origin
+15 J13-28 14.55 15.45 Main Supply
15 J13-3 15.45 14.55 Main Supply
+5.2 J13-2, 27 5.044 5.356 Main Supply
5.2 J13-1, 26 5.356 5.044 Main Supply
+5 VD J3-64, 65, 129,
130
5.044 5.356 Main Supply