Multitone personality
The PSG multitone personality provides a full featured, flexible configuration menu for
multitone signals ranging from 2 to 64 tones, Figure 11. In-band or out-of band IMD test
signals can quickly be configured using the easy to navigate table editor, Figure 12.
Enable/disable tones and change relative tone spacing, power, and initial phase
conveniently from the instrument front panel or remotely over the GPIB or LAN interface.
A. Set carrier frequency
250 kHz to 20 GHz
tones are placed symmetrically around carrier
B. Set the amplitude of the PSG signal
C. Set the number of tones
2 to 64
D. Set relative tone spacing
100 Hz to 80 MHz
depends on number of active tones
E. Select fixed or random phase initialization
F. Set relative tone power distribution
0 dB to 40 dB
total power is divided among the tones
G. Set and view initial tone phase
H. Quickly enable/disable individual tones
I. Store and Re-load custom multitone setups
J. Plot CCDF characteristics of the multitone signal
Figure 11. Multitone personality user interface.
A
B
C
D
E
I
J
F
G
H
Vedere la pagina 15