Agilent Technologies 22D Manuale Utente Pagina 4

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 16
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 3
4
High-voltage Passive Probes
Ideal for measuring up to 30 kV
Up to 250 MHz bandwidth
100:1 or 1000:1 attenuation
10076A makes high-voltage
measurements with ease
The Agilent 10076A 4 kV 100:1
passive probe gives you the volt-
age and bandwidth you need for
making high-voltage measure-
ments. Its compact design makes
it easier to probe today’s small
power electronics components
and its rugged construction
means it can withstand rough
handling without breaking.
Specifications for Agilent
Technologies 10076A High-Voltage
Probe
Bandwidth 250 MHz (-3dB)
Risetime < 1.4 ns
(Calculated)
Attenuation Ratio 100:1
Input Resistance 66.7 M (when
terminated into 1 M)
Input Capacitance Approx 3 pF
Maximum Input 4000 Vpk
Compensation 6-20 pF
Range
Probe Readout Yes
Cable Length 1.8 m
10076A Passive Probe
N2771A High-voltage Probe
Frequency
4000 V
1000 V
100 V
10 V
100 kHz
1 MHz
10 MHz
100 MHz
250 MHz
Volts dc + peak ac
10076A Derating Curve
Frequency
100000 V
10000 V
1000 V
100 V
10 V
1 V
16.614 k
100 kHz
500 kHz
1 MHz
10 MHz
50 MHz
U (VDC)
N2771A Derating Curve
Ordering Information for Agilent
Technologies High-voltage Probe
10076A High-voltage probe
includes one retractable
hook tip, one ground
bayonet, one IC probing
tip, one alligator ground
lead and a compensation
screwdriver
N2771A High-voltage probe
includes alligator ground
lead, 1 sharp probe tip
10077A Accessory kit for 10076A
includes one retractable
pincher tip, one ground
lead, one insulation cap,
two measuring pins and
two colored tags
N2771A High-voltage Probe
The N2771A is a 1000:1 divider
probe for the measurement of
fast high voltage signals. Up to
30 kV dc + peak ac, 10 kV rms.
The probe’s large size and rugged
construction provides superior
protection. The ground lead is fed
through the body of the probe
and protrudes behind the safety
barrier, keeping the ground con-
nection away from the high volt-
age. Typical applications include
PMT’s, motor drives, high voltage
switches, magnatrons and mod-
ern projection systems.
Bandwidth 50 MHz (-3dB)
Risetime <7 ns
Attenuation Ratio 1000:1
Input Resistance 100 M (when
terminated into 1 M)
Input Capacitance 1 pF
Compensation Range 7-25 pF
Max. Voltage 15 kV dc, 10 kV rms,
30 kV dc + peak ac
Operating 0°C to +50°C, 80% RH
Temperature
Storage Temperature -20°C to +70°C, 90% RH
Dimensions 2 cm (max width of probe
stem after handle) x 33 cm
7.5 cm (max probe width
at probe handle) x 33 cm
Vedere la pagina 3