Agilent Technologies 6000 and 54600 SeriesOscilloscope Probes and AccessoriesSelection Guide Data SheetTable of ContentsProbe Compatibility Table . .
10Mixed Signal Oscilloscope Logic Probes• Same cables used for high-performance logic analyzers• Flying leads offer flexibility and convenienceMSO pro
11Current Probes • Choice of dc-100 kHz and dc-50 MHz bandwidth• Hybrid technology to measure ac and dc• Compatible with any 1 MΩscope inputAccurate c
12Characteristics of the 1146A Current ProbeBandwidth* dc to 100 kHz (–3 dB)Current Range* 100 mV/A:100 mA to 10 A peak10 mV/A:1 to 100 A peakOutput S
13Wedge Probe Adapters• Easy connection to surface mount ICs• Safe, with no chance of shorting• Mechanically non-invasive contact• 3-, 8-, and 16-sign
14Printer Kit• Easily print screens and setups• No separate power supply required• Compatible only with 54620/40SeriesEverything you need for easy and
15CAN Trigger Module• Trigger on CAN 2.0A/B messageframes with user specified IDsand/or data• Trigger on Error frames• Differential CAN• Acknowledge O
16CAN Trigger Module (continued)Specifications/Characteristics N2758ACompatibility 54621D, 54622D, 54641D, 54642DProbe Dedicated Probe module – DB9 co
17E5850A Time-correlation fixture for Agilent logic analyzer and oscilloscope Unleash the complementary power of a logic analyzer and an oscilloscopeE
18PC ConnectivityGet scope data into your PC withAgilent IntuiLink without programming• Ideal for documentation and archiving• Works in familiar Micro
19PC Connectivity (continued)Standard USB, Ethernet/LAN andGPIB interfaces on 6000 SeriesHigh-speed USB 2.0 device,10/100 Base-T LAN and GPIBinterface
2Probe Compatibility TableFor ordering information whenreplacing your probe or probeaccessory: Refer directly to thepage number listed in the table of
20Miscellaneous AccessoriesTestmobile The sturdy Agilent 1183ATestmobile for use with 54600Series oscilloscope makes sharingyour scope easy. Its large
www.agilent.comMICROSOFT, WINDOWS, WINDOWS NT, VISUAL STUDIO .NET, VISUAL BASIC and the VISUAL BASIC Logo areregistered trademarks of Microsoft Corpor
3• Designed for optimal performancewith your Agilent 6000 and 54600Series scope• 1:1 and 10:1 attenuation• 20 MHz to 500 MHzRugged, high-quality probe
4High-voltage Passive Probes• Ideal for measuring up to 30 kV• Up to 250 MHz bandwidth• 100:1 or 1000:1 attenuation10076A high-voltage probeThe Agilen
5High Frequency Active Differential ProbeAgilent 1130A InfiniiMax High-Performance Active Probe System• 1.5 GHz InfiniiMax probe system• InfiniiMax pr
6High Frequency Active Differential Probe (continued)Agilent 1130A InfiniiMax High-Performance Active Probe SystemOrdering Information for Agilent Inf
7Active Differential Probes• 20 MHz to 1.5 GHz bandwidth• Switchable attenuation• Measure up to 600 V CAT III and1000 V CAT IIN2772A 20 MHz Differenti
8High-Frequency Active Single-ended ProbeAgilent 1156A High-bandwidth Active Single-ended Voltage• 1.5 GHz probe bandwidth; < 233 ps rise/fall time
9Active Single-ended Probes• Up to 800 MHz bandwidth• 10:1 attenuation• Compatible with 6000 Series300 MHz - 1 GHz or 54640 SeriesoscilloscopesAgilent
Commenti su questo manuale