Specifications
Specifications describe the instrument's warranted performance. Non-warranted values are described as typical. All specifica-
tions apply after a 30-minute warm-up phase with 50 W source/load resistance. All specifications are valid from 0°C to 55°C
ambient temperature.
8114A Specifications
Timing Characteristics
Measured at 50% amplitude at fastest transitions in continuous mode and 50
WW
source impedance.
Width: Can be set as width, duty
cycle, or trailing edge delay.
Burst Count: 2 to 65536 (single or
double pulses).
Double Pulse: Two pulses are
generated per pulse period. The
first pulse starts at the start of
the period, the double-delay sets
the delay to the start of the
second pulse. Double pulses are
available in all trigger modes
except External Width.
Delay: Delay, phase or % of period.
Double pulse delay: Double pulse
and delay are mutually exclusive.
The delay between double pulses
can be set as delay or % of period
(minimum period 134 ns)
Duty cycle: Set between 0.1% and
100% (subject to width limits and
period specifications).
Figure 1 shows the specified
operating range for actual duty
cycle and amplitude. Note that in
double pulse mode the actual
duty cycle is twice the displayed
value.
Repeatability: Is typically four
times better than accuracy.
Frequency range
1 Hz to 15.00 MHz
Timing resolution
(period, width)
3 digits, 100 ps best case
RMS jitter
(period, width, delay)
(± 0.05% ± 25 ps for period < 100ns)
Period range
66.7 ns to 999 ms
Accuracy
± 5% ± 100 ps
Width range
10.0 ns to 150 ms (max: period  10.0 ns)
Accuracy
± 5% ± 500 ps
Fixed delay
42
ns typical
{1}
Additional variable delay range
0.00 ns to 999
ms(max: period - 4 ns)
Accuracy
± 5% ± 1 ns
Resolution
3 digits, 10 ps best case
Transition time (10/90)
50
W
into 50
W
:
<7 ns (amplitude > 5 V)
High-Z into 50
W
:
<12
ns (amplitude >10 V)
Note: [1] Measured between Trigger Output and Output
3
0
20
40
60
80
100
10 20 30 40 50 V
0
16
36.9
Duty Cycle
%
Amplitude (50 Ohm into 50 Ohm)
Specified Operating Range (Single Pulses)
28.1V
0V
Figure 1
Vedere la pagina 2
1 2 3 4 5 6 7

Commenti su questo manuale

Nessun commento