See the TRUE performance of your designs.
The 86100D DCA-X is the premier solution for accurate and precise measurements
on high-speed digital designs from 50 Mb/s to over 80 Gb/s. Applications include:
Optical—Transceiver design and manufacturing compliance test
Electrical—ASIC/FPGA/IC design and channel characterization
TDR/TDT/S-parameter—Serial bus design, cable, and PCB channel
characterization
The DCA-X provides powerful analysis and measurement insight for the
novice and expert user alike:
Scope, eye diagram and mask testing
Jitter and amplitude analysis
Equalization, de-embedding, and embedding
Phase locked loop (PLL) analysis
Phase noise analysis
Agilent 86100D
Wide-Bandwidth Oscilloscope
Mainframe and Modules
Vedere la pagina 0
1 2 3 4 5 6 ... 23 24

Sommario

Pagina 1 - Mainframe and Modules

DCA-XSee the TRUE performance of your designs.The 86100D DCA-X is the premier solution for accurate and precise measurements on high-speed digital des

Pagina 2 - Table of Content

10De-embedding/embedding capability(86100D-SIM InfiniiSim-DCA)Improve insight and design margins and comply with new standards based measurements. Inf

Pagina 3 - Benefits

11Equalization/deep memory waveform capture/Matlab interface(86100D-2011) Accelerate your design cycle using these powerful tools: • Built-in linear

Pagina 4

12Phase locked loop (PLL) and phase noise measurements (86100DU-4001)Phase Locked Loops (PLL) are used in a wide variety of applications including cl

Pagina 5

13Remote Access Software, connected or offl ine operation (N1010A FlexDCA)The FlexDCA user interface that comes standard on the 86100D DCA-X is also a

Pagina 6 - 86100D DCA-X Overview

1486105C - Engineered for highest fl exibility 9 GHz optical/20 GHz electrical, 750 to 1650 nm – SMF and MMFThe 86105C has the widest coverage of data

Pagina 7

1586116C-04065 GHz optical/80 GHz electrical module, SMFWith more than 70 GHz characteristic optical bandwidth and over 93 GHz characteristic electric

Pagina 8

1686117A - Engineered for highest waveform fi delity 50 GHz dual channel electricalThe Agilent 86117A provides designers and manufacturers with a cost-

Pagina 9

17Time Domain Refl ectometry/Transmission (TDR/TDT)54754A - Engineered for novice and expert usersDifferential & single-ended TDR/TDT moduleThe Agi

Pagina 10 - MATLAB – custom measurements

18Clock Recovery83496B-100 - Engineered for fl exibility and performanceElectrical clock recovery module with phase noise analysis capabilityIncrease e

Pagina 11 - Requires 86100D-ETR

19Precision Timebase86100DThe 86100D DCA-X wide-bandwidth oscilloscope uses a built-in timebase to acquire and display waveforms. While the standard t

Pagina 12 - (86100DU-400

2Overview of the Infiniium DCA-XThe 86100D DCA-X can be viewed as four powerful instruments in one:A full function oscilloscope providing high-fidelit

Pagina 13

20ProbesActive ProbesThe DCA Series oscilloscopes are designed to work with all Agilent InfiniiMax probing systems. The InfiniiMax system is comprised

Pagina 14

21• N1020A 6GHz Single-Ended Probe and positioner • N1021B 18GHz Differential Probe Kit • 54006A 6 GHz Passive Divider Probe Kit N1021B 18GHz Diffe

Pagina 15 - Dual Electrical Modules

22DCA Accessories• 11898A Extender module for plug-in modules • 86101-60005 Filler panel• 1150-8021 USB keyboard (included with 86100D)• 0960-2670

Pagina 16

23Agilent Technologies OscilloscopesMultiple form factors from 20 MHz to >90 GHz | Industry leading specs | Powerful applicationsComplementary

Pagina 17

Windows® is a U.S. registered trademark of Microsoft Corporation.Remove all doubtOur repair and calibration services will get your equipment back to y

Pagina 18 - Clock Recovery

3The DCA-X provides users with a variety of benefits:Improved margins, differentiated products Standards are continually moving towards faster and fas

Pagina 19 - Precision Timebase

4Dual user interfaces A dual user interface comes standard. FlexDCA enables next generation measurement capability while the classic DCA-J user interf

Pagina 20

5One-touch operationCustomizable multipurpose key can be confi gured to print/save screen shots, save waveforms or load a favorite setup.Analog control

Pagina 21 - Passive probes

6Applications include:Optical• Transceiver design and manufacturing compliance testElectrical• ASIC/FPGA/SERDES/IC design and characterizationTDR/TDT/

Pagina 22

7Dual user interfaces (standard with every 86100D)The 86100D DCA-X includes two user interfaces for even greater ease-of-use and 100% backwards compat

Pagina 23 - Complementary Products

8Oscilloscope measurements(standard with every 86100D)Highest accuracy waveforms. Wide-bandwidth, low-noise, and low-jitter samples result in accurate

Pagina 24 - October 1, 2009

9Jitter analysis (86100D-2001)As data rates increase in both electrical and optical applications, jitter is an ever increasing design and measurement