U7232A DisplayPort Electrical Performance Compliance Test Application
Method of Implementation
Agilent Technologies
s
13
Source Spread Spectrum Clocking
(SSC) Differential Tests (Normative &
Informative)
Probing for Source Spread Spectrum Clocking (SSC) Differential
Te s t s 112
Source Spread Spectrum Clocking (SSC) Differential Test 114
This section provides the guidelines for the source spread spectrum
clocking (SSC) differential tests using an Agilent 8 GHz or greater
Infiniium oscilloscope, 1168A or 1169A probes, and the DisplayPort
Electrical Performance Compliance Test Application. In this SSC test, the
Modulation Frequency and Modulation Deviation tests are normative tests
whereas Deviation HF Variation tests are informative tests.