Programming Reference
Default Values, Standard Settings
Default Values, Standard Settings
Parameter *RST, Default Values
:ARM : EWIDth:STATe OFF
:FREQuency 100kHz
:IMPedance 50
:LEVel +1.00V
:PERiod 10.00
µ
s
:SENSe EDGE
:SLOPe POS
:SOURce IMMediate
:DISPlay [:WINDow] [:STATe] ON
:MMEMory :CATalog? not applicable
:CDIRectory not applicable
:COPY not applicable
:DELete not applicable
:INITialize not applicable
:LOAD :STATe not applicable
:STORe:STATe not applicable
:OUTPut[1][:NORMal][:STATe] OFF
:IMPedance[:INTernal] 50
:EXTernal 50.0
:POLarity NORMal
[:SOURce]:CURRent[1][:LEVel][:IMM][:AMPL] 20.0mA (from 50
into 50
)
:OFFset 0.0mA (from 50
into 50
)
:HIGH +10.0mA (from 50
into 50
)
:LOW –10.0mA (from 50
into 50
)
:LIMit[:HIGH] +10.0mA