3-96 Real-Time I/Q Baseband Generator User’s and Programming Guide
Softkey Reference ESG Family Signal Generators
F Options UN8 and 202
FIX4 Press this softkey to select a 4-bit repeating sequence data pattern and
make it the active function. Enter the desired 4-bit pattern.
When you select FIX4 as a data pattern for modulated transmissions
that are not framed (
Data Format Pattern Framed is set to Pattern), FIX4
appears in the Data field in the top line of the text area of the display.
When you select FIX4 for configuring the timeslot data fields, the 4-bit
pattern is displayed in either the Data field (all formats) or the
• B field (DECT)
• E field (EDGE and GSM)
• TCH field (PDC and PHS)
all of which are located near the bottom of the text area of the display.
Range: 0000 through 1111
Default Value: 0000
Softkey Locations
Custom:
Mode > Custom > Data > FIX4
Other Formats: Mode > TDMA >
desired format
> Data > FIX4
DECT: Mode > TDMA > DECT > Data Format Pattern Framed >
Configure Timeslots > Configure Traffic Bearer > B field > FIX4
FIX4 is also located in the B field menus found in the portable part
Configure Traffic Bearer menu and the radio fixed part and portable
part Low Capacity menus, and also in the radio fixed part and
portable part Configure Custom menus.
EDGE:
Mode > TDMA > EDGE (Rev 8.3.0 Release 1999) >
Data Format Pattern Framed > Configure Timeslots > Configure Normal >
E > FIX4
Or: Mode > TDMA > EDGE (Rev 8.3.0 Release 1999) >
Data Format Pattern Framed > Configure Timeslots > Timeslot Type >
Custom > Configure Custom > Data > FIX4
GSM: Mode > TDMA > GSM > Data Format Pattern Framed >
Configure Timeslots > Configure Normal > E > FIX4
FIX4 is also located in the Configure Custom menu, and in the E
menus found in the Configure Sync and Configure Access menus.
Commenti su questo manuale