Chapter 6 141
8662A/63A Commands
8662A/63A Compatible Commands
Table 6-1 8662A/63A Commands & Equivalent SCPI Sequences
Command Description 8662 8663 Equivalent SCPI Command Sequence
@1 Write require service mask N N not supported
@2 Deferred execution mode N N
not supported
@3 Immediate execution mode N N
not supported
+D +dBm Y Y DBM
AM
AM modulation
See also: Table 6-2 on page 148
Y
AM:DEPTh <val> <units>
AM:TRAC ON
FM:STAT OFF
AM:STAT ON
Y
AM:DEPTh <val> <units>
AM:TRAC ON
AM:STAT ON
AO Amplitude off Y Y OUTPut:STATe OFF
AP Amplitude Y Y
POW:REF:STATe OFF
POWer:AMPL <val> <units>
OUTPut:STATe ON
See also: Table 6-2 on page 148
AS|BLSQ Auto sequence N N
not supported
BP BPSK modulation N
not supported
CT Configure trigger Y Y
no equivalent SCPI command sequence
−D
−dBm
Negates the power value.
YYDBM
DB dB Y Y DB
DG Degree Y DEG
DM dBm Y Y DBM
DN
Decrement
Passes DOWN as parameter of active function command.
YYSee Table 6-2 on page 148
FA Start frequency Y Y
See W2, W3, W4,
and Table 6-2 on page 148
FB Stop frequency Y Y
See W2, W3, W4,
and Table 6-2 on page 148