Chapter 13 227
SCPI Command Reference
E5061A/E5062A commands
13. SCPI Command
Reference
:CALC{1-4}:FUNC:POIN?
Syntax :CALCulate{[1]|2|3|4}[:SELected]:FUNCtion:POINts?
Description For the active trace of channel 1 (:CALC1) to channel 4 (:CALC4) (specified with the
:CALC{1-4}:PAR{1-4}:SEL command), reads out the number of data pairs of the analysis
result of the :CALC{1-4}:FUNC:EXEC command.
For the analysis of the mean value or the search of the maximum value, 1 is always read
out; for the search of all peaks or the search of all targets, the total number of searched
measurement points is read out. (Query only)
Query response {numeric}<newline><^END>
Example of use
10 OUTPUT 717;":CALC1:FUNC:POIN?"
20 ENTER 717;A
Related commands :CALC{1-4}:FUNC:EXEC on page 225
:CALC{1-4}:FUNC:DATA? on page 221
:CALC{1-4}:PAR{1-4}:SEL on page 286
Equivalent key No equivalent key is available on the front panel.