Chapter 13 319
SCPI Command Reference
E5061A/E5062A commands
13. SCPI Command
Reference
:DISP:WIND{1-4}:ANN:MARK:ALIG
Syntax :DISPlay:WINDow{[1]|2|3|4}:ANNotation:MARKer:ALIGn[:STATe] {ON|OFF|1|0}
:DISPlay:WINDow{[1]|2|3|4}:ANNotation:MARKer:ALIGn[:STATe]?
Description For channel 1 (:WIND1) to channel 4 (:WIND4), turns ON/OFF the alignment mode in
which the display positions of the marker values for each trace are aligned relative to trace
1.
Parameters
Query response {1|0}<newline><^END>
Example of use
10 OUTPUT 717;":DISP:WIND1:ANN:MARK:ALIG OFF"
20 OUTPUT 717;":DISP:WIND1:ANN:MARK:ALIG?"
30 ENTER 717;A
Equivalent key [Marker Fctn] - Annotation Options - Align
Description
ON or 1 (preset value) Turns ON the alignment mode using trace 1 as the
reference.
OFF or 0 Turn OFF the alignment mode.