Agilent Technologies Cell Phone S GSM Manuale Utente Pagina 139

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 381
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 138
4-33
Screens
Cell Control - Test Mode
Cell Control - Test Mode
This screens allows you to test the mobile phone without a call being set up.
1. GSM900
E-GSM
DCS1800
PCS1900
This field selects the type of mobile that is to be tested.
Choices GSM 900
E-GSM
DCS 1800
PCS 1900
2. Active
Cell/TestMode/C
W Generator
This field selects the test mode of the Agilent 8922M/S. The types are:
Active Cell - this mode sets up a call between the mobile phone and the
Agilent 8922M/S.
Test Mode - this mode sets the Agilent 8922M/S to work with a mobile phone
running a test mode. This mode allows you to transmit either BCCH only or
BCCH and TCH and measures an independent GSM signal.
CW Generator - this mode sets the Agilent 8922M/S as a signal generator.
Vedere la pagina 138
1 2 ... 134 135 136 137 138 139 140 141 142 143 144 ... 380 381

Commenti su questo manuale

Nessun commento