4-99
Screens
Pwr Ramp, Fall Edge
Pwr Ramp, Fall Edge
NOTE When multiburst is turned on, display update rate for power versus time and phase
traces will be slowed down while multiple bursts are collected.
This view displays the falling portion of the amplitude envelope with the amplitude
mask superimposed. The vertical range is 40 to +5 dBm. The horizontal range is
+144 to +156 or +84 to +96 bit periods depending on the burst type.
1. Amplitude This is a copy of the RF analyzer Amplitude field. This is the amplitude to be
assumed at the selected input port.
Range RF IN/OUT: 27.9 to +41.0 dBm. AUX RF IN: 58.0 to +20.0
dBm.
See Also Screens: RF Generator/RF Analyzer (RF Analyzer) Chapter 3:
Specifications
2. Marker These fields display the time and level at the current marker position.