Agilent EasyEXPERT Users Guide Vol. 2, Edition 1 6- 23
Remote Control Interface
STANDby Subsystem
STANDby Subsystem
Describes STANDby subsystem command used for the standby function.
:STANDby:STATe
Sets or returns the SMU standby function ON/OFF status.
Syntax :STANDby:STATe mode
:STANDby:STATe?
Parameter mode Standby function ON or OFF, 0|OFF|1|ON. Data type is Bool.
0 | OFF: Standby function OFF
1 | ON: Standby function ON
Query response mode<newline>
0 (OFF) or 1 (ON) is returned. Data type is Bool.
Example :STAND:STAT ON
:STAND:STAT?