34
U2600A
Product characteristics and general specifi cations
REMOTE INTERFACE
Hi-Speed USB 2.0*•
USBTMC-USB488•
[1]
POWER REQUIREMENT
+12 VDC (TYPICAL)•
2 A (MAX) input rated current•
Installation Category II•
POWER CONSUMPTION
+12 VDC, 260 mA maximum
OPERATING ENVIRONMENT
Operating temperature from 0 °C to +55 °C•
Relative humidity at 15% to 85% at 40 °C (non-condensing)•
Altitude up to 2000 meters•
Pollution Degree 2•
For indoor use only•
STORAGE COMPLIANCE
–20 °C to 70 °C
SAFETY COMPLIANCE
Certifi ed with:
IEC 61010-1:2001/EN 61010-1:2001 (2nd Edition)•
USA: ANSI/UL 61010-1:2004•
Canada: CSA C22.2 No.61010-1:2004•
EMC COMPLIANCE
IEC 61326-1:2002/EN 61326-1:1997+A2:2001+A3:2003•
CISPR 11: 1990/EN 55011:1990-Group 1 Class A•
Canada: ICES-001:2004•
Australia/New Zealand: AS/NZS CISPR 11:2004•
SHOCK AND VIBRATION
Tested to IEC/EN 60068-2
IO CONNECTOR
100-pin SCSI-II connector
DIMENSION (W × D × H)
Module dimension:
120.00 mm × 182.40 mm × 44.00 mm (with plastic casing) •
105.00 mm × 174.54 mm × 25.00 mm (without plastic casing)•
Terminal block dimension:
158.00 mm × 118.60 mm × 51.50 mm•
WEIGHT
565 g (with plastic casing)•
370 g (without plastic casing)•
WARRANTY
Three years for U2600A series DAQ devices
Three months for standard shipped accessories
Product outlook and dimensions
Front view
Rear view
Top view
Standard shipped accessories
AC/DC Power adapter•
Power cord•
USB extension cable•
L-Mount kit (used with modular •
product chassis)
Agilent USB Modular Products Quick •
Start Guide
Agilent Measurement Manager for •
U2600A Series Quick Start Guide
Agilent USB Modular Products •
Reference CD-ROM
Agilent Automation-Ready CD-ROM •
(contains the Agilent IO Libraries Suite)
Certifi cate of Calibration•
Optional accessories
U2903A Terminal block and SCSI-II •
100-pin connector with 1-meter cable
U2904A Terminal block and SCSI-II •
100-pin connector with 2-meter cable
120.00 mm
182.40 mm
44.00 mm
[1]
Compatible with Microsoft Windows operating systems only.
*If remote connections are necessary, a E5813A USB/LAN hub can
be used. Please go to the product’s user guide for more information.
Commenti su questo manuale