U2802A
Features
Up to 31 thermocouple inputs
Supports thermocouple type J, K, 
R, S, T, N, E, and B
Up to 10 V voltage input range
Open thermocouple detection
Built-in isothermal terminal 
construction
Built-in thermistor
Built-in zeroing function
Sampling rate of 500 kSa/s for 
overall module
Sampling rate of 10 kSa/s total for 
all channels in thermocouple mode
Configurable for voltage input 
or thermocouple input mode
independently on each channel
Introduction
The Agilent U2802A is a 31-channel thermocouple signal conditioning module
with a built-in thermistor for cold junction compensation. The U2802A is
designed to convert low input voltage signals (less than ±100 mV) from a
thermocouple into an output voltage range suitable for data acquisition devices
(±10 V). The U2802A device is to be used in conjunction with the Agilent
U2355A or U2356A model DAQ device to enable temperature measurements
using thermocouples. It works as a standalone device attached to a single DAQ
device via two SCSI-II 68 conductor cables. The U2802A is compatible with eight
standard thermocouple types and is suitable for a wide range of applications in
various industrial environment.
U2802A 31-Channel Thermocouple Input Device
Applications
The U2802A thermocouple input device is designed for robust and demanding
industrial applications. This product is suitable and ideal for thermocouple
measurement applications such as,
product thermal analysis and characterization,
environmental chamber profiling,
process monitoring in consumer electronics markets,
material properties testing in education environments,
study of electronic temperature properties, and
appliances testing.
Features to meet your demands
31 input channels that can be independently configured to either 
differential thermocouple input mode, single-ended voltage input mode,
or differential voltage input mode using two input channels set to voltage
input mode
Supports the standard thermocouple types defined in the NIST ITS-90 
Thermocouple Database
Error detection for open thermocouple channels
Built-in isothermal construction on terminal block for improved 
measurement accuracy
Built-in zeroing function to compensate for overall system offset errors due 
to temperature drift and long term drift
Up to ±10 V input voltage range for 
higher voltage inputs
Quick and easy USB setup
Robust, cost-effective, and user 
friendly