:SEARch Commands 26
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide 557
:SEARch:SERial:SPI:PATTern:DATA
(see page 790)
Command Syntax
:SEARch:SERial:SPI:PATTern:DATA <string>
<string> ::= "0xnn...n" where n ::= {0,..,9 | A,..,F | X}
The :SEARch:SERial:SPI:PATTern:DATA command specifies the data value
when searching for SPI events.
The width of the data value is specified using the
:SEARch:SERial:SPI:PATTern:WIDTh command.
Query Syntax
:SEARch:SERial:SPI:PATTern:DATA?
The :SEARch:SERial:SPI:PATTern:DATA? query returns the current data
value setting.
Return Format
<string><NL>
<string> ::= "0xnn...n" where n ::= {0,..,9 | A,..,F | X}
See Also Chapter 26, “:SEARch Commands,” starting on page 531