Ordering information
86100D Infiniium DCA-X mainframe
86100D Hardware Options
86100D-STR Standard trigger
86100D-ETR Enhanced trigger
86100DU-ETR Enhanced trigger upgrade kit
86100D-PTB Precision timebase integrated in the mainframe
86100DU-PTB Upgrade mainframe with integrated precision
timebase
86100D-GPI GPIB card interface installed (default)
86100D-GPN No GPIB card interface
86100D-090 Removable hard drive
86100D-092 Internal hard drive (default)
86100D Software Options
86100D-xxx are permanent fixed-node licenses
installed by the factory
86100DU-xxx are permanent fixed-node licenses
installed by the customer (software upgrades)
86100DT-xxx are permanent transportable licenses
installed by the customer
The “-xxx” option code provides the same functionality
independent of the prefix (i.e., 86100D or 86100DU or 86100DT)
86100D-061 MATLAB - Basic Oscilloscope Package
86100D-062 MATLAB - Standard Oscilloscope Package
86100D-200 Enhanced Jitter analysis software
86100DT-200 Transportable 86100DU-200 license
86100D-201 Advanced waveform analysis software
86100D-202 Enhanced impedance and S-parameter software
86100D-300 Amplitude analysis/RIN/Q-factor
86100DU-400 PLL and Jitter Spectrum software
1
86100DU-401 Advanced EYE analysis software
1
86100D-SIM InfiniiSim-DCA software
86100D-500 Productivity Package software
N1012A OIF CEI compliance and debug application
N1014A SFF-8431 compliance and debug application
N1019A user-defined application
N1081A IEEE 802.3 KR/KR4 application
N1082A IEEE802.3 CR4/CR10 application
N1083A IEEE802.3 nAUI/nPPI application
N1084A IEEE802.3 KR4/CR4 application
Misc Options
86100D-AFP Module slot filler panel
86100D-AX4 Rack mount flange kit
86100D-AXE Rack mount flange kit with handles
86100D-UK6 Commercial cal certificate with test data
86100DU-WN7 Upgrade to Windows 7 operating system
1. Fixed node customer installed or transportable customer installed (86100DU or 86100DT). Not available as a factory-installed license.
2. This module is not compatible with the 86100A and 86100B DCA mainframes. If you want to upgrade older DCAs, contact Agilent Technologies to discuss current trade-in deals
3. System impulse response correction calibration provides a unique calibration file for the optical channel(s). The FlexDCA user interface uses this calibration file to create ideal reference
receiver responses for more accurate and consistent transceiver compliance testing. IRC also allows reference receivers to be defined at any data rate within +/- 50% of the hardware
response. This allows optical receivers to significantly extend their operating range.
4. A 15 Gb/s filter is provided with Option 281 and 282 that closely approximates the response required for 16X Fibre Channel compliance testing. Contact Agilent for a special option that
verifies compliance of the 86105D-281 and 86115D-282 to the 16X Fibre Channel reference receiver specification.
NOTE:
Options 200, 201, and SIM require Option ETR (enhanced trigger).
Option 300 requires Options 200 and ETR.
Option 400 requires Microsoft Office Excel 2007/2010
Option 401 requires Options ETR/200 for DDPWS measurement
and Excel for amplitude interference measurements
Optical/electrical modules
86105C 9 GHz optical channel; single-mode and multimode,
amplified (750 to 1650 nm)
20 GHz electrical channel
86105C-100 155 Mb/s through 8.5 Gb/s (choose 4 filter rates
from Options 86105C-110 through 86105C-195)
86105C-110 155 Mb/s
86105C-120 622 Mb/s (also covers 614 Mb/s)
86105C-130 1.063 Gb/s
86105C-140 1.244/1.250 Gb/s (also covers 1.229 Mb/s)
86105C-150 2.125 Gb/s
86105C-160 2.488/2.500 Gb/s (also covers 2.458 Gb/s)
86105C-170 2.666 Gb/s
86105C-180 3.125 Gb/s (also covers 3.072 Gb/s)
86105C-190 4.250 Gb/s
86105C-193 5.0 Gb/s
86105C-195 6.250 Gb/s (also covers 6.144 Gb/s)
86105C-200 8.5, 9.953, 10.3125, 10.519, 10.664, 10.709, 11.096,
11.317 Gb/s
86105C-300 Combination of rates available in 86105C-100 and
86105C-200
86105D
2
20 GHz optical channel; single-mode and
multimode, (750-1650 nm); filters for 8.5, 9.953,
10.3125, 10.519, 10.664, 10.709, 11.096, 11.317,
14.025 Gb/s; 35 GHz electrical channel
86105D-100 Identical capability as 86105D, 14.025 Gb/s filter
not included
86105D-200 Identical capability as 86105D, only filter provided
is 14.025 Gb/s
86105D-IRC
3
System impulse response correction calibration
86105D-281 34 GHz optical channel, filters for 15, 25.78 , 27.95,
28.05 Gb/s (contact Agilent for additional
14.025 Gb/s filter)
4
. 50 GHz electrical channel
86115D
2
20 GHz multi-optical port plug-in module;
single-mode and multimode (750-1650 nm); filters
for 8.5, 9.953, 10.3125, 10.519, 10.664, 10.709,
11.096, 11.317, 14.025 Gb/s
86115D-002 Two optical channels with filters for all rates listed