Agilent Technologies 86100D Manuale Utente Pagina 31

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 36
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 30
31
Ordering information
(8.5 to 14.025 Gb/s)
86115D-102 Identical capability as 86115D-002, 14.025 Gb/s
filters not included
86115D-142 Identical capability as 86115D-002, only filters
provided are 14.025 Gb/s
86115D-282 Two optical channels with filters for 15, 25.78,
27.95, 28.05 Gb/s (contact Agilent for 14.025 Gb/s
filter)
4
86115D-004 Four optical ports with filters for all rates listed (8.5
to 14.025 Gb/s) mulitplexed to two optical
channels through 2 integral 1X2 optical switches
86115D-104 Identical capability as 86115D-004, 14.025 Gb/s
filters not included
86115D-144 Identical capability as 86115D-004, only filters
provided are 14.025 Gb/s
86115D-IRC System impulse response correction calibration
86116C
2
40 to 65 GHz optical / 80 GHz electrical sampling
module, 1300 to 1620 nm
86116C-IRC
3
System impulse response correction calibration
This module is not compatible with the 86100A and 86100B DCA
mainframes. If you want to upgrade older DCAs, contact Agilent
Technologies to discuss current trade-in deals.
All optical modules have FC/PC connectors installed on each optical port.
Other connector adapters available as options are: Diamond HMS-10, DIN,
ST and SC.
86116C
1
40 to 65 GHz optical / 80 GHz electrical sampling
module, 1300 to 1620 nm
Select exactly one reference receiver option:
86116C-025: 40 GHz opt./80 GHz elec. channels,
17.0/25.8/27.7 Gb/s reference receiver
86116C-041: 65 GHz opt./80 GHz elec. channels,
39.81/41.25/43.02 Gb/s reference receiver
Dual/Quad electrical channel modules
86112A Dual 20 GHz electrical channels
86112A-HBW Dual 30 GHz electrical channels
86117A Dual 50 GHz electrical channels
86118A Dual 70 GHz electrical remote sampling channels
86118A-H01 Differential De-Skew
N1045A
2
2/4 Port 60 GHz electrical remote head
N1045A-02F 2 channel remote head, 1.85 mm, female
N1045A-02M 2 channel remote head, 1.85 mm, male
N1045A-04F 4 channel remote head, 1.85 mm, female
N1045A-04M 4 channel remote head, 1.85 mm, male
TDR/TDT modules
1. Fixed node customer installed or transportable customer installed (86100DU or 86100DT). Not available as a factory-installed license.
2. This module is not compatible with the 86100A and 86100B DCA mainframes. If you want to upgrade older DCAs, contact Agilent Technologies to discuss current trade-in deals
3. System impulse response correction calibration provides a unique calibration file for the optical channel(s). The FlexDCA user interface uses this calibration file to create ideal reference
receiver responses for more accurate and consistent transceiver compliance testing. IRC also allows reference receivers to be defined at any data rate within +/- 50% of the hardware
response. This allows optical receivers to significantly extend their operating range.
4. A 15 Gb/s filter is provided with Option 281 and 282 that closely approximates the response required for 16X Fibre Channel compliance testing. Contact Agilent for a special option that
verifies compliance of the 86105D-281 and 86115D-282 to the 16X Fibre Channel reference receiver specification.
54754A
1,5
Differential TDR module with dual 18 GHz
TDR/electrical channels
N1055A
2
35/50 GHz, 2/4 port, TDR/TDT remote head
N1055A-32F 35 GHz, 2 channel remote head, 2.92 mm, female
N1055A-32M 35 GHz, 2 channel remote head, 2.92 mm, male
N1055A-34F 35 GHz, 4 channel remote head, 2.92 mm, female
N1055A-34M 35 GHz, 4 channel remote head, 2.92 mm, male
N1055A-52F 50 GHz, 2 channel remote head, 1.85 mm, female
N1055A-52M 50 GHz, 2 channel remote head, 1.85 mm, male
N1055A-54F 50 GHz, 4 channel remote head, 1.85 mm, female
N1055A-54M 50 GHz, 4 channel remote head, 1.85 mm, male
Precision timebase module
86107A Precision timebase reference module
86107A-010 2.5 and 10 GHz clock input capability
86107A-020 10 and 20 GHz clock input capability
86107A-040 10, 20 and 40 GHz clock input capability
Clock recovery modules
1
The following modules provide a recovered clock from the data
signal for triggering at indicated data rates:
83496B 50 Mb/s to 7.1 Gb/s Clock recovery module. This
module is not compatible with the 86100A and
86100B DCA mainframes. If you want to upgrade
older DCAs, contact Agilent Technologies and ask
for current trade-in deals.
83496B-100 Single-ended and differential electrical with
integrated signal taps
83496B-101 Single Mode (1260-1360 nm and
1490-1600 nm) and multimode (830-860 nm and
1260-1360 nm) optical. Integrated signal
taps. Single-ended or differential electrical inputs
(no signal taps)
83496B-200 Increase operating range to 50 Mb/s to 14.2 Gb/s
83496BU-200 Data rate 0.05 Gb/s to 14.2 Gb/s upgrade
83496B-201 Shift operating range to 7.1 to 14.2 Gb/s
83496BU-201 Shift operating range to 7.1 to 14.2 Gb/s upgrade
83496B-300 Add tunable loop bandwidth “golden PLL” capabil-
ity
83496BU-300 Adjustable loop bandwidth upgrade
External clock recovery solutions
Vedere la pagina 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36

Commenti su questo manuale