Agilent Technologies E8364C Manuale Utente Pagina 73

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 145
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 72
69
Table 23. 85054D Calibration Kit
Standard Configuration and Standard Power Range
(E836xB/C)
Applies to the, E836xB/C analyzers, 85054D (Type-N) calibration kit, 85132F flexible test port cable set with 85130C adapter set, and a full
2-port calibration. Also applies to the following condition:
Environmental temperature 23° ±3 °C, with < 1 °C deviation from calibration temperature
Specification (dB) Description
0.045 to
2 GHz
2 to
18 GHz
Directivity 40 34
Source Match 39 29
Load Match 40 34
Reflection Tracking
±0.003
+0.02/°C
±0.027
+0.02/°C
Transmission Tracking
±0.013
+0.02/°C
±0.136
+0.02/°C
Vedere la pagina 72
1 2 ... 68 69 70 71 72 73 74 75 76 77 78 ... 144 145

Commenti su questo manuale

Nessun commento