:SEARch Commands 25
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 567
:SEARch:GLITch:LESSthan
(see page 860)
Command Syntax
:SEARch:GLITch:LESSthan <less_than_time>[<suffix>]
<less_than_time> ::= floating-point number in NR3 format
<suffix> ::= {s | ms | us | ns | ps}
The :SEARch:GLITch:LESSthan command sets the maximum pulse width
duration for the selected :SEARch:GLITch:SOURce.
Query Syntax
:SEARch:GLITch:LESSthan?
The :SEARch:GLITch:LESSthan? query returns the pulse width duration
time for :SEARch:GLITch:SOURce.
Return Format
<less_than_time><NL>
<less_than_time> ::= floating-point number in NR3 format.
See Also Chapter 25, “:SEARch Commands,” starting on page 557
":SEARch:GLITch:SOURce" on page 571
":SEARch:GLITch:QUALifier" on page 569
":SEARch:MODE" on page 560