748 Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
30 :WGEN Commands
:WGEN:FUNCtion:PULSe:WIDTh
(see page 860)
Command Syntax
:WGEN:FUNCtion:PULSe:WIDTh <width>
<width> ::= pulse width in seconds in NR3 format
For Pulse waveforms, the :WGEN:FUNCtion:PULSe:WIDTh command
specifies the width of the pulse.
The pulse width can be adjusted from 20 ns to the period minus 20 ns.
Query Syntax
:WGEN:FUNCtion:PULSe:WIDTh?
The :WGEN:FUNCtion:PULSe:WIDTh? query returns the currently set pulse
width.
Return Format
<width><NL>
<width> ::= pulse width in seconds in NR3 format
See Also "Introduction to :WGEN Commands" on page 744