:SEARch Commands 25
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 581
:SEARch:TRANsition:TIME
(see page 860)
Command Syntax
:SEARch:TRANsition:TIME <time>[suffix]
<time> ::= floating-point number in NR3 format
[suffix] ::= {s | ms | us | ns | ps}
The :SEARch:TRANsition:TIME command sets the time of the transition to
search for. You can search for transitions greater than or less than this
time.
Query Syntax
:SEARch:TRANsition:TIME?
The :SEARch:TRANsition:TIME? query returns the current transition time
value.
Return Format
<time><NL>
<time> ::= floating-point number in NR3 format
See Also Chapter 25, “:SEARch Commands,” starting on page 557