Agilent Technologies InfiniiVision 3000 DSO-X 3054A Manuale di Servizio Pagina 723

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 970
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 722
:WAVeform Commands 29
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 723
The :WAVeform:POINts:MODE? query returns the current points mode.
Setting the points mode will affect what data is transferred. See the
discussion above.
Return Format
<points_mode><NL>
<points_mode> ::= {NORMal | MAXimum | RAW}
See Also "Introduction to :WAVeform Commands" on page 709
":WAVeform:DATA" on page 717
":ACQuire:POINts" on page 192
":WAVeform:VIEW" on page 736
":WAVeform:PREamble" on page 724
":WAVeform:POINts" on page 720
":TIMebase:MODE" on page 631
":ACQuire:TYPE" on page 199
":ACQuire:COUNt" on page 190
Vedere la pagina 722
1 2 ... 718 719 720 721 722 723 724 725 726 727 728 ... 969 970

Commenti su questo manuale

Nessun commento