698 Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
28 :TRIGger Commands
:TRIGger:TV:MODE
(see page 860)
Command Syntax
:TRIGger:TV:MODE <mode>
<mode> ::= {FIEld1 | FIEld2 | AFIelds | ALINes
| LFIeld1 | LFIeld2 | LALTernate}
The :TRIGger:TV:MODE command selects the TV trigger mode and field.
Old forms for <mode> are accepted:
Query Syntax
:TRIGger:TV:MODE?
The :TRIGger:TV:MODE? query returns the TV trigger mode.
Return Format
<value><NL>
<value> ::= {FIE1 | FIE2 | AFI | ALIN | LFI1 | LFI2 | LALT}
See Also "Introduction to :TRIGger Commands" on page 641
":TRIGger:TV:STANdard" on page 701
":TRIGger:MODE" on page 648
<mode> Old Forms Accepted
FIEld1 F1
FIEld2 F2
AFIelds ALLFields, ALLFLDS
ALINes ALLLines
LFIeld1 LINEF1, LINEFIELD1
LFIeld2 LINEF2, LINEFIELD2
LALTernate LINEAlt