9. Disconnect lower eight bits (bits 0 through 7) from test connector. Attach
upper eight bits (bits 8 through 15) to the test connector. Repeat steps 3, 4, 6,
7 and 8 until the upper bits of all pods have been tested (pods 1 through 5).
Clock,
Qualifier, and
Data Inputs
Test 4
Description: This test verifies the minimum swing voltages of the input probes and
the maximum clock rate of the HP 1650B\ 51B when it is in single phase mode.
Specification:
Minimum swing: 600 mV peak-to-peak.
HP 1650B Clock repetition rate: Single phase is 35 MH z maximum.
HP 1651B Clock repetition rate: Single phase is 25 MH z maximum.
Clock pulse width:
10 ns at threshold.
Equipment:
Pulse Generator ............................... HP 8161A/020
Oscilloscope ..................................... HP 54502A
50 Ohm Feedthru (2) .............................. HP 10100C
Test Connectors see figure 3-1..........................(2)
Procedure:
1. Connect the HP 1650B\ 51B and test equipment as in figure 3-18. In order to
most accurately measure the amplitude of the test signals from the pulse
generator, high impedance scope probes should be used to look at the signal
levels at the output of the pulse generator.
Note In this setup, only eight channels are tested at a time to minimize loading. Ground
lead must be connected to ensure accurate test results. It is recommended that all
eight channel grounds be connected.
Figure 3-18. Setup for Data Test 4
HP 1650B/1651B Performance Tests
Service Manual 3-15
Vedere la pagina 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 110 111