38 B* Diode Slope See Comments. A typical trace will be flat for the first and
last few divisions. This trace represents the
change in slope of power-in vs. voltage out.
The slope is constant (zero) for both the log
and linear portions of the diode curve. Only
the transitional area will show something
other than a flat line.
39 R* Diode Slope See Comments. As above but for the R* diode.
40 B* Amplitude -Raw
Voltage vs. Power
For Service Use Displays the Diode characteristic of the
broadband diode in the B detector. The Y
axis displays (dB per mV) while the X axis
displays raw input power.
41 R* Amplitude -Raw
Voltage vs. Power
For Service Use Displays the Diode characteristic of the
broadband diode in the R detector. The Y
axis displays (dB per µV) while the X axis
displays raw input power.
42 Load Match Typical response
is below 20 dB
Displays the stored Load Match of the RF
OUT port for the ET analyzers or for the ES
analyzers PORT 1 and PORT2.