Performance Checks 8712ET/ES and 8714ET/ES
Test Port Output RF Network Analyzers
1-62 Service Guide
Table 1-8 Test Port Output (continued)
8712ET/ES and 8714ET/ES Test Port Output
Description Specification Supplemental Information
Output Power (continued)
Power Resolution 0.01 dB
Attenuator Switch Points:
8712ET:
50 Ω−1, 11, 21, 31, 41, 51 dBm, nom.
75 Ω−4, 14, 24, 34, 44, 54 dBm, nom.
8712ES:
50 Ω−3, 13, 23, 33, 43, 53 dBm, nom.
75 Ω−6, 16, 26, 36, 46, 56 dBm, nom.
8714ET:
50 Ω−6, 16, 26, 36, 46, 56 dBm, nom.
75 Ω−9, 19, 29, 39, 49, 59 dBm, nom.
8714ES:
50 Ω−8, 18, 28, 38, 48, 58 dBm, nom.
75 Ω−11, 21, 31, 41, 51 dBm, nom.